Maximum length of pipe portion AB
Short answer
Maximum allowable length of portion AB is 1806 m, with BC about 1194 m, satisfying the limiting pressure head of -2 m gauge at summit B.
Two reservoirs whose difference of level is 15 m are connected by a pipe ABC whose highest point B is 2 m below the level in the upper reservoir A. The portion AB has a diameter of 200 mm, and the portion BC has a diameter of 150 mm, the friction coefficient being the same for both portions. Total length of pipe ABC is 3 km. Find the maximum allowable length of the portion AB if the pressure head at B is not to be more than 2 m below atmospheric pressure. Neglect the secondary losses and take f = 0.012. [Figure: free surface of reservoir 1; pipe rising from A to the summit B (2 m below the upper water level) then falling to C in reservoir 2; = 200 mm, = 150 mm; level difference 15 m]
Data. m, m, m, m, . Summit B is 2 m below the upper water level; pressure head at B m (gauge). Secondary (minor) losses are neglected.
Let . By continuity , so .
Condition at B (limiting pressure)
Energy equation from the upper reservoir surface (datum, ) to B, which is 2 m below the surface (), with m:
(here per metre).
Condition for the total head
Level difference = friction in AB + friction in BC (no minor losses):
Solve
Substitute from (1) into (2):
Check: m, so m/s, m/s, m³/s; friction in AB m and in BC m, which add to 15 m.
Answer: The maximum allowable length of portion AB m (so BC is about 1194 m).
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Three reservoirs: pipe AEC length and level B · Hydraulics, chapter 3
- Pipe passing over barrier between reservoirs · Hydraulics, chapter 2
- Pipe over hill with cavitation limit · Hydraulics, chapter 2
- Three reservoirs with two parallel pipes · Hydraulics, chapter 3
- Three reservoirs with 250 mm concrete pipes · Hydraulics, chapter 3 · asked 2×
- Siphon with 90 mm pipe, number and length · Hydraulics, chapter 2
- Flow between reservoirs (15 cm and 25 cm pipe) · Hydro Power, chapter 1
- Design pipes AB and BC, 20,000 population, f = 0.04 · Water Supply Engineering, chapter 7
- Flow between reservoirs (20 cm and 30 cm pipe) · Hydro Power, chapter 1
- Hardy-Cross network discharge AB, BC, AD, CD · Water Supply Engineering, chapter 7