- Practice · 6 marks
Stages of a generalized measurement system
Short answer
The sensor/transducer (thermocouple) converts the measurand to an electrical signal. Signal conditioning amplifies, filters, and compensates (cold-junction compensation, linearization). The output stage displays the result (digital temperature readout). Calibration links the final output to the measurand.
Draw the block diagram of a generalized measurement system and explain the function of each stage, taking a thermocouple-based temperature indicator as the example.
A generalized measurement system converts the measured quantity (measurand) into a form suitable for observation. It has three main stages: sensing/transducing, signal conditioning, and output (readout).
Measurand +-----------+ +-------------+ +----------+
------------>| Sensor / |-->| Signal |-->| Terminal |
(temperature) | transducer| | conditioning| | (readout)|
+-----------+ +-------------+ +----------+
Stage I Stage II Stage III
(modify, amplify)
^
Power supply / calibration
Functions of the stages
- Sensor-transducer stage (detector): senses the measurand and gives an output related to it. It should respond only to the measurand and should not load the source.
- Signal-conditioning stage: modifies the transducer output into a suitable form. It includes amplification, filtering, bridge circuits, analog-to-digital conversion, linearization and modulation.
- Terminating (readout) stage: presents the result to the observer or controller. It may be an indicator, recorder, display or data logger.
Thermocouple temperature indicator
- Sensor: the thermocouple produces a small emf (mV) proportional to the difference between the hot- and cold-junction temperatures.
- Signal conditioning: a cold-junction compensation circuit adds the reference emf, an amplifier raises the mV signal, a filter removes noise, and linearization corrects the nonlinear emf-temperature relation. An ADC converts the signal to digital form.
- Readout: a digital display or chart recorder shows the temperature in C.
Calibration against a known standard temperature links the readout to the measurand.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Thermocouple time constant and frequency response · Instrumentation and Measurement, chapter 4
- Thermocouple laws and emf calculation · Instrumentation and Measurement, chapter 5
- Step response of a first-order system · Instrumentation and Measurement, chapter 4
- Characteristics and response of zero-order system · Instrumentation and Measurement, chapter 4
- Measurement and measurement system block diagram · Instrumentation I, chapter 1
- Block diagram of digital communication system · Data Communication, chapter 1 · asked 8×
- DMM block diagram: V, I and R measurement · Basic Electronics Engineering, chapter 7
- Block diagram of a two-stage RC circuit · Control Systems, chapter 2