- 2078 Chaitra · 5 marks
Line efficiency increases with voltage
Short answer
For given power, line current I = P/(√3 V cosφ), so loss 3I²R ∝ 1/V². Thus efficiency η ≈ 1 − (Pρl)/(a V² cos²φ) improves as voltage increases because loss decreases quadratically.
"Transmission line efficiency increases with the increase in voltage." Justify the statement mathematically.
Transmission efficiency rises with voltage because, for the same power, a higher voltage means a smaller current and hence much smaller loss.
Consider a 3-phase line delivering power at line voltage and power factor . Let be the resistance per phase, .
Line current
Line loss
Efficiency
For given , , , and , the loss term is proportional to . So as increases, the loss falls and increases.
Example
A line with /phase carries 10 MW at 0.8 pf.
| Voltage | Current | Loss | Efficiency |
|---|---|---|---|
| 33 kV | 218.7 A | 1.435 MW | 87.5 % |
| 66 kV | 109.3 A | 0.359 MW | 96.5 % |
| 132 kV | 54.7 A | 0.090 MW | 99.1 % |
Doubling the voltage cuts the loss to one quarter.
Related results
- For a fixed percentage loss, the conductor area needed is , so the conductor volume (and cost) falls as .
- The percentage voltage drop also falls as , so regulation improves.
- The limit is the cost of insulation, towers and switchgear, which rises with voltage; this sets the economic transmission voltage.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Significance of transmission voltage level, 132 vs 400 kV · Power System Analysis I, chapter 1
- Short line 40 km, 381 MVA: regulation and efficiency · Power System Analysis I, chapter 6
- 33 kV, 15 MW line: efficiency and regulation · Power System Analysis I, chapter 6
- Regulation and efficiency of 100 km, 110 kV line · Power System Analysis I, chapter 6 · asked 2×
- 110 km, 110 kV line: sending end, regulation, efficiency · Power System Analysis I, chapter 6 · asked 2×
- Long line voltage and current at intermediate point · Power System Analysis I, chapter 5
- Justify higher voltage/more circuits for more power · Transmission and Distribution System Design, chapter 2
- T/F: economic voltage vs number of circuits · Transmission and Distribution System Design, chapter 2
- Reducing Ferranti effect mathematically · High Voltage Engineering, chapter 3
- T/F: power transfer capability vs line length · Transmission and Distribution System Design, chapter 2 · asked 2×