Switched capacitor filter for (s+200)(s+800)/(s+400)²
Short answer
Split T(s) into two first-order inverting sections. Use fc=10 kHz and C=100 pF. Compute switched capacitors CR1 = aC/fc, CR2 = bC/fc. Section 1 (zero 200, pole 400): CR1=2 pF, CR2=4 pF. Section 2 (zero 800, pole 400): CR1=8 pF, CR2=4 pF.
What is a switched capacitor filter? Design a switched capacitor filter to realize the transfer function T(s) = (s+200)(s+800)/(s+400)².
Switched-capacitor filter
A switched-capacitor (SC) filter is an active filter in which the resistors of an active-RC filter are replaced by capacitors switched by MOS transistors driven by a clock. Each switched capacitor behaves like a resistor , so the time constants depend only on capacitor ratios and the clock frequency.
phi1 phi2
V1 o---/ ----+---- / ---o V2
|
=== C
|
GND
Two non-overlapping clock phases and at frequency :
- During the capacitor connects to : charge .
- During it connects to : charge .
Charge moved from to in one clock period: . Average current:
This holds when is much higher than the signal frequencies.
Design for
Split into two first-order sections:
DC gain and high-frequency gain .
Building block
A first-order section with an op-amp, input admittance and feedback admittance :
With the zero is at and the pole at . Each resistor is then replaced by a switched capacitor , i.e.
+-------| C2 |-------+
+----[SC: CR2]-------+
| |
Vi o--+--| C1 |--+ |
| | |
+-[SC: CR1]+-----(-) |
A -----+----o Vo
GND-----(+)
Choices: clock = 10 kHz (the highest critical frequency, 800 rad/s ≈ 127 Hz, is far below ), integrating capacitors = 100 pF.
| Section | Zero | Pole | |||
|---|---|---|---|---|---|
| 200 | 400 | 100 pF | 2 pF | 4 pF | |
| 800 | 400 | 100 pF | 8 pF | 4 pF |
Each section inverts, so the cascade of two gives with the correct sign.
Vi -->[ T1: C=100p, CR1=2p, CR2=4p ]-->
[ T2: C=100p, CR1=8p, CR2=4p ]--> Vo
(fc = 10 kHz)
Answer: = 10 kHz; section 1: = 100 pF, = 2 pF, = 4 pF; section 2: = 100 pF, = 8 pF, = 4 pF.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Why switched capacitors; design for 100–400 rad/s peak · Filter Design, chapter 9 · asked 2×
- Active filter advantages; bilinear zero 800, pole 400 · Filter Design, chapter 6
- SC filter applications; design for 100–400 rad/s peak · Filter Design, chapter 9
- SC filter: 6 dB peak at 400 rad/s · Filter Design, chapter 9
- SC MOS filter for 400–1600 rad/s peak · Filter Design, chapter 9 · asked 4×
- Inverting realization of 7(s+400)/(s+200) · Filter Design, chapter 6
- Corner stresses of 400 x 800 column (200 kN) · Concrete Technology and Masonry Structure, chapter 8 · asked 7×
- Transfer function of RC low-pass filter · Signals and Systems, chapter 5 · asked 2×
- Transfer function of DT low pass filter · Signals and Systems, chapter 6
- Corner stresses of 400 x 800 column (250 kN) · Concrete Technology and Masonry Structure, chapter 8 · asked 7×