Design pipes AB and BC, source RL 1050 m

Short answer

Without break pressure, AB = 20 mm, BC = 15 mm. The highest class must withstand 140 m static head in BC. Installing a break pressure tank at B reduces the static head to 60 m, allowing a lower class and BC redesigned to 20 mm.

Design pipelines AB and BC for the following pipe network. A minimum pressure of 1 kg/cm2^2 is required at the tap. Take Hazen William constant as 100. Which pipe class has to be designed? Is there any option to reduce high level pipe class and how?

[Figure: Source A (RL = 1050 m); pipe AB, L = 320 m, carries 0.35 lps to B, Tap no. 1 (RL = 970 m); pipe BC, L = 250 m, carries 0.2 lps to C, Tap no. 2 (RL = 910 m).]

Residual pressure at each tap = 1 kg/cm² = 10 m. Source A has RL 1050 m, so HGL at A = 1050 m. Flows: AB = 0.35 lps, BC = 0.20 lps.

Method

Use the Hazen-Williams equation in SI units:

hf=10.67 L Q1.852C1.852D4.87h_f = \frac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}

with QQ in m³/s, LL and DD in m. For each pipe the available head is (HGL at upstream end − ground RL of the tap − required residual head). The gradient S=H/LS = H/L gives the calculated diameter, the next larger commercial size is adopted, and the real head loss and residual head are then checked. Commercial sizes (nominal bore): 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mm and so on. Constant C = 100.

Pipe AB

  • Discharge Q=0.350Q = 0.350 lps, length L=320L = 320 m
  • HGL at A = 1050.00 m; ground RL at B = 970 m; residual head required = 10 m
  • Available head H=1050.00−970−10=70.00H = 1050.00 - 970 - 10 = 70.00 m
  • Gradient S=H/L=70.00/320=0.21875S = H/L = 70.00/320 = 0.21875
  • From hf=10.67 L Q1.852C1.852D4.87h_f = \dfrac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}: Dcalc=18.7D_{calc} = 18.7 mm, adopt commercial size 20 mm
  • Actual hf=50.456h_f = 50.456 m, HGL at B = 999.54 m, residual head = 29.54 m (≥ 10 m, OK)
  • Velocity v=Q/A=1.11v = Q/A = 1.11 m/s

Pipe BC

  • Discharge Q=0.200Q = 0.200 lps, length L=250L = 250 m
  • HGL at B = 999.54 m; ground RL at C = 910 m; residual head required = 10 m
  • Available head H=999.54−910−10=79.54H = 999.54 - 910 - 10 = 79.54 m
  • Gradient S=H/L=79.54/250=0.31818S = H/L = 79.54/250 = 0.31818
  • From hf=10.67 L Q1.852C1.852D4.87h_f = \dfrac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}: Dcalc=14.0D_{calc} = 14.0 mm, adopt commercial size 15 mm
  • Actual hf=56.761h_f = 56.761 m, HGL at C = 942.78 m, residual head = 32.78 m (≥ 10 m, OK)
  • Velocity v=Q/A=1.13v = Q/A = 1.13 m/s

Summary

PipeQ (lps)L (m)Calc. D (mm)Adopted D (mm)h_f (m)Residual (m)v (m/s)
AB0.3532018.72050.4629.541.11
BC0.225014.01556.7632.781.13

Pipe class

The pipe class must resist the maximum static (zero-flow) head:

  • Section AB: static head at B = 1050 − 970 = 80 m
  • Section BC: static head at C = 1050 − 910 = 140 m (14 kg/cm² = 1.4 MPa)

So pipe BC must be of a high class that can withstand at least 140 m (for example GI heavy or HDPE PN 16 / PN 20), while AB needs only a class for 80 m (GI medium or PN 10). The high-class pipe is costly.

Reducing the high class

Provide a break pressure tank (BPT) at B (RL 970 m). The tank breaks the pressure to zero (atmospheric) and starts a new hydraulic line from RL 970 m, so the static head in BC becomes 970 − 910 = 60 m only, and the whole scheme can use a pipe class for 80 m (PN 10 / GI medium).

Redesign of BC with BPT at B: available head H=970−910−10=50H = 970 - 910 - 10 = 50 m, S=0.200S = 0.200, Dcalc=15.4D_{calc} = 15.4 mm, adopt 20 mm, hf=13.98h_f = 13.98 m, residual head = 46.02 m, v=0.64v = 0.64 m/s. A pressure-reducing valve at B could also be used.

Answer: AB = 20 mm, BC = 15 mm (without BPT). Highest class needed is for 140 m static head in BC; with a BPT at B the BC static head falls to 60 m and a lower class (for 80 m) is enough, with BC = 20 mm.

✓ Answer checked by Claude Opus 5.5 (high effort)