- 2068 Chaitra · 8 marks
Design pipelines AB, BC, AD; 1 kg/cm2 at tap
Short answer
Use Hazen-Williams equation with C=100. Pipe AB (0.25 lps, 120 m) adopts 20 mm, pipe BC (0.1 lps, 150 m) adopts 15 mm, pipe AD (0.5 lps, 160 m) adopts 25 mm. Residual heads exceed 10 m at all taps.
Design pipelines AB, BC and AD for the following pipe network. A minimum pressure of 1 kg/cm is required at the tap. Take Hazen William constant C = 100.
[Figure: Source RL = 985 m at A. AB: L = 120 m, 0.25 lps, to B with Tap no. 1 (RL = 960 m). BC: L = 150 m, 0.1 lps, to C with Tap no. 2 (RL = 920 m). AD: L = 160 m, 0.5 lps, to D with Tap no. 3 (RL = 940 m).]
Residual pressure = 1 kg/cm² = 10 m; C = 100. HGL at A = 985 m. Discharges as given: AB = 0.25 lps, BC = 0.10 lps, AD = 0.50 lps.
Method
Use the Hazen-Williams equation in SI units:
with in m³/s, and in m. For each pipe the available head is (HGL at upstream end − ground RL of the tap − required residual head). The gradient gives the calculated diameter, the next larger commercial size is adopted, and the real head loss and residual head are then checked. Commercial sizes (nominal bore): 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mm and so on. Constant C = 100.
Pipe AB
- Discharge lps, length m
- HGL at A = 985.00 m; ground RL at B = 960 m; residual head required = 10 m
- Available head m
- Gradient
- From : mm, adopt commercial size 20 mm
- Actual m, HGL at B = 974.85 m, residual head = 14.85 m (≥ 10 m, OK)
- Velocity m/s
Pipe BC
- Discharge lps, length m
- HGL at B = 974.85 m; ground RL at C = 920 m; residual head required = 10 m
- Available head m
- Gradient
- From : mm, adopt commercial size 15 mm
- Actual m, HGL at C = 965.42 m, residual head = 45.42 m (≥ 10 m, OK)
- Velocity m/s
Pipe AD
- Discharge lps, length m
- HGL at A = 985.00 m; ground RL at D = 940 m; residual head required = 10 m
- Available head m
- Gradient
- From : mm, adopt commercial size 25 mm
- Actual m, HGL at D = 968.53 m, residual head = 28.53 m (≥ 10 m, OK)
- Velocity m/s
Summary
| Pipe | Q (lps) | L (m) | Calc. D (mm) | Adopted D (mm) | h_f (m) | Residual (m) | v (m/s) |
|---|---|---|---|---|---|---|---|
| AB | 0.25 | 120 | 18.5 | 20 | 10.15 | 14.85 | 0.80 |
| BC | 0.1 | 150 | 10.9 | 15 | 9.43 | 45.42 | 0.57 |
| AD | 0.5 | 160 | 21.4 | 25 | 16.47 | 28.53 | 1.02 |
Static head is highest at C (985 − 920 = 65 m), so the pipes BC (and AB feeding it) must be of a class suitable for at least 65 m.
Answer: AB = 20 mm, BC = 15 mm, AD = 25 mm.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Design pipes AB, BC, AD (min pressure 1.1 kg/cm2) · Water Supply Engineering, chapter 7 · asked 2×
- Design pipes AB and BC, source RL 1050 m · Water Supply Engineering, chapter 7
- Design pipelines AB, BC and CD, C = 120 · Water Supply Engineering, chapter 7
- Design pipes AB and BC, source RL 180 m · Water Supply Engineering, chapter 7
- Design pipelines AB and BC, C = 100, 10 m head · Water Supply Engineering, chapter 7
- Hardy-Cross network discharge AB, BC, AD, CD · Water Supply Engineering, chapter 7