- 2074 Chaitra · 8 marks
Design pipelines AB, BC and CD, C = 120
Short answer
AB = 32 mm, BC = 20 mm, CD = 15 mm. Residual heads: 15.7 m at B, 19.0 m at C, 17.1 m at D, all exceeding the 12 m minimum. Velocities range 0.31–0.57 m/s.
A layout of water distribution is as shown below. Design pipelines AB, BC and CD considering Hazen-William's constant of 120. Minimum pressure required at B, C and D is 12 m of water.
[Figure: Source at A; AB: discharge = 0.25 lps, length = 700 m; BC: discharge = 0.15 lps, length = 500 m; CD: discharge = 0.1 lps, length = 600 m. Reduced levels: A = 500 m, B = 480 m, C = 465 m, D = 440 m.]
Hazen-Williams constant C = 120; the residual pressure at B, C and D must be at least 12 m. HGL at A = RL of A = 500 m.
Method
Use the Hazen-Williams equation in SI units:
with in m³/s, and in m. For each pipe the available head is (HGL at upstream end − ground RL of the tap − required residual head). The gradient gives the calculated diameter, the next larger commercial size is adopted, and the real head loss and residual head are then checked. Commercial sizes (nominal bore): 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mm and so on. Constant C = 120.
Pipe AB
- Discharge lps, length m
- HGL at A = 500.00 m; ground RL at B = 480 m; residual head required = 12 m
- Available head m
- Gradient
- From : mm, adopt commercial size 32 mm
- Actual m, HGL at B = 495.72 m, residual head = 15.72 m (≥ 12 m, OK)
- Velocity m/s
Pipe BC
- Discharge lps, length m
- HGL at B = 495.72 m; ground RL at C = 465 m; residual head required = 12 m
- Available head m
- Gradient
- From : mm, adopt commercial size 20 mm
- Actual m, HGL at C = 484.01 m, residual head = 19.01 m (≥ 12 m, OK)
- Velocity m/s
Pipe CD
- Discharge lps, length m
- HGL at C = 484.01 m; ground RL at D = 440 m; residual head required = 12 m
- Available head m
- Gradient
- From : mm, adopt commercial size 15 mm
- Actual m, HGL at D = 457.09 m, residual head = 17.09 m (≥ 12 m, OK)
- Velocity m/s
Summary
| Pipe | Q (lps) | L (m) | Calc. D (mm) | Adopted D (mm) | h_f (m) | Residual (m) | v (m/s) |
|---|---|---|---|---|---|---|---|
| AB | 0.25 | 700 | 28.1 | 32 | 4.28 | 15.72 | 0.31 |
| BC | 0.15 | 500 | 18.2 | 20 | 11.71 | 19.01 | 0.48 |
| CD | 0.1 | 600 | 14.5 | 15 | 26.92 | 17.09 | 0.57 |
The pipe sizes are small because the flows are only a few tenths of a litre per second, and the velocities (0.3–0.6 m/s) are low; they are acceptable for a rural system with the limited head available. Maximum static head is at D: 500 − 440 = 60 m, so a pipe class for 60 m (about 0.6 MPa) is needed.
Answer: AB = 32 mm, BC = 20 mm, CD = 15 mm.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Design pipelines AB and BC, C = 100, 10 m head · Water Supply Engineering, chapter 7
- Design pipelines AB, BC, AD; 1 kg/cm2 at tap · Water Supply Engineering, chapter 7
- Design pipes AB and BC, source RL 1050 m · Water Supply Engineering, chapter 7
- Design pipes AB and BC, A RL 210 m, 44 and 18 lps · Water Supply Engineering, chapter 7
- Hardy-Cross network discharge AB, BC, AD, CD · Water Supply Engineering, chapter 7
- Design pipes AB, BC, AD (min pressure 1.1 kg/cm2) · Water Supply Engineering, chapter 7 · asked 2×
- Pipe outlet minimum water level, 50 lps · Irrigation and Drainage Engineering, chapter 7
- Verify suggested discharge distribution (Hardy Cross) · Hydraulics, chapter 3
- Hose siphon discharge and minimum pressure · Hydraulics, chapter 2
- Force on 120° bend, 300 lps · Fluid Mechanics, chapter 7 · asked 2×