Methods of stream flow measurement

Short answer

Bucket: collect whole flow, Q=V/t for small streams. Float: surface speed L/t × 0.85 × area. Weir: V-notch Q=1.4H^2.5 or rectangular with Francis formula. Salt dilution: inject salt, measure downstream conductivity curve. Current meter: velocity-area from point measurements. Flow duration curve: flow vs % time exceeded; design flow chosen at 90–95% exceedance.

Explain the methods used to measure the flow of a small stream for a micro hydro plant (bucket, float, weir, salt dilution and current meter). What is a flow duration curve and how is it used in selecting the design flow?

Bucket method

The whole stream is diverted into a container of known volume and the filling time is measured. Q=V/tQ = V/t. It is accurate and used for very small flows (below about 10 L/s).

Float (velocity-area) method

Mark a straight length of channel (say 10–20 m), measure the time tt for a float to travel it, and the average cross-sectional area AA. Surface velocity vs=L/tv_s = L/t; mean velocity v=k vsv = k\,v_s with k≈0.8k \approx 0.8–0.85. Q=A vQ = A\,v. It is simple but approximate.

Weir method

A sharp-edged rectangular or V-notch weir is built across the stream and the head HH over the crest is measured. For a rectangular weir with end contractions Q=1.84 (L−0.1nH)H3/2Q = 1.84\,(L - 0.1nH)H^{3/2} and for a 90° V-notch Q=1.4H5/2Q = 1.4H^{5/2} (m³/s, metres). Accurate for small and medium streams.

Salt dilution method

A known mass of salt is dissolved and poured into the stream at one point, and the conductivity is recorded downstream where it is fully mixed. The area under the conductivity-time curve gives QQ. It suits turbulent mountain streams where other methods are difficult.

Current meter

A propeller meter measures velocity at several points (usually at 0.6 of depth) in verticals across the section. Q=∑viAiQ = \sum v_i A_i (velocity-area method). It gives the best accuracy but needs equipment.

Flow duration curve (FDC)

It is a plot of flow against the percentage of time (or days) the flow is equalled or exceeded, constructed from daily or monthly flow records sorted in descending order.

 Q
 |\
 | \___
 |     \____
 |          \______
 +------------------ % time
 0       50      100

For micro hydro the design flow is normally taken at the flow available 90–95 % of the time (dry season) so that power is dependable, and the area under the curve gives the energy available.