Canal head regulator design, Q 150
Short answer
Crest level 251.20 m; waterway 20 m clear (4 bays of 5 m), overall 24.5 m; d/s cut-off 3.3 m; impervious floor length 42 m.
A canal carrying 150 m³/s is to take off from the headwork. The HFL and average bed level of river is 257 m and 250 m respectively. The canal bed level, full supply level and pond level are 249.5 m, 253.0 m and 254.0 m respectively and Lacey's silt factor is equal to unity. Fix the crest level and water way of canal head regulator and also determine the length of impervious floor if safe exit gradient GE = 1/6. Draw the conceptual sketch of canal head regulator.
Data and assumptions
- Discharge m³/s; pond level m; full supply level of canal m; canal bed m; u/s HFL m; Lacey's ; safe exit gradient .
- The river bed is at 250.00 m; the crest is kept 1.2 m above the river bed (under-sluice crest level): m.
- The regulator is designed as a broad-crested weir for the free-flow condition, .
1. Crest level
Head over the crest at pond level: m. Depth of canal water over the crest: m, which is less than m, so the weir is not drowned and the free-flow formula applies.
2. Waterway
Provide 4 bays of 5.0 m clear width (20 m) with 3 piers 1.5 m thick; overall width m. Check: with the gates fully open, m³/s m³/s, so the waterway is adequate and the gates are partly lowered to pass the design discharge.
3. Impervious floor (Khosla's exit gradient)
Discharge intensity m²/s. Lacey's scour depth:
The d/s cut-off is taken down to below the d/s water level: bottom level m, so the d/s cut-off depth below the floor (canal bed) is m; adopt m. U/s cut-off m. Maximum static head (canal dry, water at pond level): m. The gates are closed during floods; the HFL (257 m) fixes the top of the piers and gates. Exit gradient:
(Using .) Check: . Provide a floor of 42 m: about 1/3 on the u/s side and 2/3 downstream, with thickness 1.5 m under the gates tapering to 0.8 m.
4. Other features
- Top of piers and gates: HFL + 1.0 m free-board. Vertical lift steel gates with a hoist deck.
- D/s of the floor: inverted filter and loose stone apron (length about ), and wing walls splayed at 45°.
Summary
| Item | Value |
|---|---|
| Crest level | 251.20 m |
| Waterway | 20 m clear (4 bays of 5 m), overall 24.5 m |
| Cut-offs u/s / d/s | 2.5 m / 3.3 m |
| Floor length | 42 m |
Conceptual sketch (longitudinal section):
HFL / pond ~~~~~~~~~~|gates|~~~~~~ canal FSL ~~~~~
river ________|piers|________
bed ________| crest (1.2 m above |_____ canal bed
|d1 u/s floor river bed) d/s floor | d2
(impervious) inverted filter
<------------ b (Khosla, GE = 1/6) --------->
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Canal head regulator design, Q 200 · Irrigation and Drainage Engineering, chapter 7
- Design cross and head regulator, Q 125 · Irrigation and Drainage Engineering, chapter 7
- Weir waterway and crest levels, 16000 m3/s · Irrigation and Drainage Engineering, chapter 5
- Sarda fall: Q 12, bed level 103 m · Irrigation and Drainage Engineering, chapter 7
- Stepwise design of head regulator · Irrigation and Drainage Engineering, chapter 7
- Design procedure: cross and distributary head regulator · Irrigation and Drainage Engineering, chapter 7
- Oxidation pond design, 250 m³/d; theory · Sanitary Engineering, chapter 7
- Design: 250 m head plant at Q25% · Power Plant Design, chapter 4 · asked 14×
- Design: 250 m head plant, 66 kV double circuit · Power Plant Design, chapter 4 · asked 13×
- Design: 250 m head plant, 35 km line · Power Plant Design, chapter 4 · asked 12×
All Irrigation and Drainage Engineering chapter 7 questions →