Design cross and head regulator, Q 125

Short answer

Cross regulator: crest 116.70 m, clear waterway 20 m (overall 24.5 m), floor 26 m, cut-off depth 2.8 m. Head regulator: sill 117.20 m, clear waterway 4.0 m, floor 12 m, d/s cut-off 3.6 m.

Design a cross regulator and head regulator for a channel which takes off from the parent channel with following data: (i) Discharge of parent channel = 125 cumecs (ii) Discharge of distributary channel = 20 cumecs (iii) FSL of parent channel U/S = 120 m, D/S = 119.7 m (iv) Bed width of Parent channel U/S = 50 m, D/S = 45 m (v) Depth of water in the parent channel U/S = 3 m, D/S = 3 m (vi) FSL of distributary = 119 m (vii) Bed width of distributary = 20 m (viii) Full supply depth of distributary = 1.8 m (ix) Silt factor = 0.8 (x) Assume safe exit gradient = 1/6.

A cross regulator (in the parent canal, downstream of the off-take) holds the water level up for the distributary. The distributary head regulator controls the supply into the distributary. Both are designed as gated structures with Khosla's floor.

Data

Parent canal: Q=125Q = 125 m³/s, FSL u/s 120.00 m and d/s 119.70 m, depth 3 m, bed width 50 m (u/s) and 45 m (d/s), so bed levels are 117.00 m (u/s) and 116.70 m (d/s). Distributary: Q=20Q = 20 m³/s, FSL 119.00 m, bed width 20 m, depth 1.8 m, so bed 117.20 m. f=0.8f = 0.8, safe exit gradient 1/6.

A. Cross regulator (6 marks)

1. Discharge through it: Qcr=125−20=105Q_{cr} = 125 - 20 = 105 m³/s. The permitted afflux (head loss) is Δh=120.00−119.70=0.30\Delta h = 120.00 - 119.70 = 0.30 m.

2. Crest and waterway: the crest (sill) is kept at the d/s bed level, 116.70 m. With the gates fully raised the opening acts as an orifice of depth D=3.0D = 3.0 m, Cd=0.8C_d = 0.8:

B=QcrCd D2g Δh=1050.8×3.0×2×9.81×0.30=18.03 m\begin{aligned} B &= \frac{Q_{cr}}{C_d\,D\sqrt{2g\,\Delta h}} = \frac{105}{0.8\times3.0\times\sqrt{2\times9.81\times0.30}} = 18.03\ \text{m} \end{aligned}

Provide 4 bays of 5 m = 20 m clear with 3 piers of 1.5 m; overall width 24.5 m. With 20 m the actual afflux is 0.244 m <0.3< 0.3 m, safe.

3. Floor: discharge intensity q=105/24.5=4.29q = 105/24.5 = 4.29 m²/s, Lacey scour R=1.35(q2/f)1/3=3.84R = 1.35(q^2/f)^{1/3} = 3.84 m. D/s cut-off bottom =119.70−1.5R=113.94= 119.70 - 1.5R = 113.94 m, so d=116.70−113.94d = 116.70 - 113.94, adopt d=2.8d = 2.8 m (u/s cut-off 2.0 m). Maximum static head Hs=120.00−116.70=3.30H_s = 120.00 - 116.70 = 3.30 m (d/s dry):

1πλ=d6Hs=2.86×3.30⇒λ=5.07, α=9.08, b=αd=25.4 m\frac{1}{\pi\sqrt{\lambda}} = \frac{d}{6H_s} = \frac{2.8}{6\times3.30} \Rightarrow \lambda = 5.07,\ \alpha = 9.08,\ b = \alpha d = 25.4\ \text{m}

Provide floor length 26 m with 1.2 m thickness tapering to 0.8 m, u/s and d/s cut-offs, d/s inverted filter and stone apron.

B. Distributary head regulator (6 marks)

1. Discharge Q=20Q = 20 m³/s; head loss from the parent FSL 120.00 m to the distributary FSL 119.00 m is Δh=1.00\Delta h = 1.00 m.

2. Waterway: sill at distributary bed level 117.20 m, opening depth D=1.8D = 1.8 m, Cd=0.8C_d = 0.8:

B=200.8×1.8×2×9.81×1.0=3.14 mB = \frac{20}{0.8\times1.8\times\sqrt{2\times9.81\times1.0}} = 3.14\ \text{m}

Provide 2 bays of 2.0 m (4.0 m clear, pier 1.2 m; overall 5.2 m). With the gates fully open the loss is only 0.61 m, so the gates throttle the flow to give the required discharge.

3. Floor: q=20/5.2=3.85q = 20/5.2 = 3.85 m²/s, R=3.57R = 3.57 m. D/s cut-off to 119.00−1.5R=113.65119.00 - 1.5R = 113.65 m, so d=3.6d = 3.6 m below the floor (117.20 m). Hs=120.00−117.20=2.80H_s = 120.00 - 117.20 = 2.80 m. For GE=1/6G_E = 1/6: λ=2.21\lambda = 2.21, α=3.26\alpha = 3.26, floor length b=11.7b = 11.7 m; provide 12 m. Floor thickness 1.0 m.

Answer: cross regulator: crest 116.70 m, clear waterway 20 m (overall 24.5 m), floor 26 m, cut-off depth 2.8 m. Head regulator: sill 117.20 m, clear waterway 4.0 m, floor 12 m, d/s cut-off 3.6 m.

 Plan: parent canal ====>====[HR]====> distributary
                       |  [CR] across parent canal
                       v       (u/s of CR: FSL 120.0)
 Section: gates | crest 116.70 | floor b | d/s cut-off d

✓ Answer checked by Claude Opus 5.5 (high effort)