Skip to main content

Short column 450x300, 1500 kN, M30

Short answer

For a 450×300 mm short column with 1500 kN axial load and biaxial moments 150 and 80 kNm, provide 8-25 mm longitudinal bars (2.91% steel) and 8 mm lateral ties at 300 mm c/c.

Design a short rectangular column of size 450 mm x 300 mm and unsupported length 3 m subjected to an axial ultimate load of 1500 kN and ultimate moments 150 kNm and 80 kNm about long major and minor axes respectively. Adopt M30 grade of concrete and Fe500 grade of steel. Sketch the final design.

Data and assumptions

  • Column 300 mm (width bb) × 450 mm (depth DD); Pu=1500P_u = 1500 kN; fck=30f_{ck} = 30 MPa, fy=500f_y = 500 MPa. Clear cover 40 mm (IS 456 cl. 26.4.2.1), 8 mm ties.
  • Moments: about major axis (x-x) MuxM_{ux} = 150 kN·m; about minor axis (y-y) MuyM_{uy} = 80 kN·m.
  • Sizes are given as b×Db \times D with D≥bD \ge b; moments MuxM_{ux} act about the major axis (depth DD) and MuyM_{uy} about the minor axis (depth bb).

Slenderness

Axislel_e (mm)Dimension (mm)le/l_e/dimType
x-x (about major)30004506.67short
y-y (about minor)300030010.00short

Both ratios are below 12, so the column is short; no additional moment is required.

Minimum eccentricity (cl. 25.4)

emin=max⁡(L500+D30, 20)e_{min} = \max\left(\frac{L}{500} + \frac{D}{30},\ 20\right)
  • About x-x: ex=3000/500+450/30=21.0e_x = 3000/500 + 450/30 = 21.0 mm (min. 20 mm); adopt 21.0 mm; Mux,min=Pue=31.5M_{ux,min} = P_u e = 31.5 kN·m
  • About y-y: ey=3000/500+300/30=16.0e_y = 3000/500 + 300/30 = 16.0 mm (min. 20 mm); adopt 20.0 mm; Muy,min=30.0M_{uy,min} = 30.0 kN·m

Design moments

  • Design moments: Mux=150.0M_{ux} = 150.0 kN·m, Muy=80.0M_{uy} = 80.0 kN·m (not less than the minimum-eccentricity values).

Longitudinal reinforcement

PufckbD=150000030×300×450=0.370\dfrac{P_u}{f_{ck} b D} = \dfrac{1500000}{30 \times 300 \times 450} = 0.370 Bars are chosen so that pp lies between 0.8% (minimum) and 4% (practical maximum; IS 456 cl. 26.5.3.1 allows 6%). The uniaxial capacities Mux1M_{ux1}, Muy1M_{uy1} at PuP_u are read from the SP-16 interaction charts for rectangular sections; here they are computed by strain compatibility with the IS 456 stress block and the design stress-strain curve of steel (same basis as the charts), with effective cover d′=40+8+ϕ/2d' = 40 + 8 + \phi/2.

Trialpp (%)d′/Dd'/DMux1M_{ux1}Muy1M_{uy1}Pu/PuzP_u/P_{uz}αn\alpha_n(Mux/Mux1)αn+(Muy/Muy1)αn(M_{ux}/M_{ux1})^{\alpha_n}+(M_{uy}/M_{uy1})^{\alpha_n}
16-16 φ2.380.124204.2118.90.5021.501.180 ✗
12-20 φ2.790.129229.4130.40.4711.451.032 ✗
8-25 φ2.910.134238.6134.30.4631.440.988 ✓

Check

Puz=0.45fckAc+0.75fyAsc=0.45×30×131073+0.75×500×3927=3242P_{uz} = 0.45 f_{ck} A_c + 0.75 f_y A_{sc} = 0.45 \times 30 \times 131073 + 0.75 \times 500 \times 3927 = 3242 kN PuPuz=15003242=0.463\dfrac{P_u}{P_{uz}} = \dfrac{1500}{3242} = 0.463, so αn=1.44\alpha_n = 1.44 (IS 456 cl. 39.6; linear between 1.0 at 0.2 and 2.0 at 0.8).

(MuxMux1)αn+(MuyMuy1)αn=(150.0238.6)1.44+(80.0134.3)1.44=0.988≤1.0\left(\frac{M_{ux}}{M_{ux1}}\right)^{\alpha_n} + \left(\frac{M_{uy}}{M_{uy1}}\right)^{\alpha_n} = \left(\frac{150.0}{238.6}\right)^{1.44} + \left(\frac{80.0}{134.3}\right)^{1.44} = 0.988 \le 1.0

The interaction condition is satisfied; the section is safe.

Provide 8-25 mm bars (Asc=3927A_{sc} = 3927 mm², p=2.91%p = 2.91\%), within 0.8% to 4%.

Lateral ties

  • Diameter ≥max⁡(ϕmax/4, 6)=max⁡(25/4,6)=6.25\ge \max(\phi_{max}/4,\ 6) = \max(25/4, 6) = 6.25 mm → provide 8 mm.
  • Pitch ≤min⁡\le \min(least lateral dimension, 16ϕmin16\phi_{min}, 300 mm) =min⁡(300,400,300)=300= \min(300, 400, 300) = 300 mm → provide 8 mm ties @ 300 mm c/c.

Detailing

CROSS-SECTION 300 x 450
    +-------------------------+
    |                         |
    |    o       o       o    |
    |                         |
    |                         |
    |                         |
    |    o               o    |
    |                         |
    |                         |
    |                         |
    |    o       o       o    |
    |                         |
    +-------------------------+
   o = 25 mm bars, ties 8 mm @ 300 c/c

Answer: 300 × 450 mm column with 8-25 mm longitudinal bars (p=2.91%p = 2.91\%) and 8 mm ties @ 300 mm c/c.

✓ Answer checked by Claude Opus 5.5 (high effort)