- Asked 2/25
- 2071 Chaitra · 14 marks
Short column 450x300, 1500 kN, M30
Short answer
For a 450×300 mm short column with 1500 kN axial load and biaxial moments 150 and 80 kNm, provide 8-25 mm longitudinal bars (2.91% steel) and 8 mm lateral ties at 300 mm c/c.
Design a short rectangular column of size 450 mm x 300 mm and unsupported length 3 m subjected to an axial ultimate load of 1500 kN and ultimate moments 150 kNm and 80 kNm about long major and minor axes respectively. Adopt M30 grade of concrete and Fe500 grade of steel. Sketch the final design.
Data and assumptions
- Column 300 mm (width ) × 450 mm (depth ); kN; MPa, MPa. Clear cover 40 mm (IS 456 cl. 26.4.2.1), 8 mm ties.
- Moments: about major axis (x-x) = 150 kN·m; about minor axis (y-y) = 80 kN·m.
- Sizes are given as with ; moments act about the major axis (depth ) and about the minor axis (depth ).
Slenderness
| Axis | (mm) | Dimension (mm) | dim | Type |
|---|---|---|---|---|
| x-x (about major) | 3000 | 450 | 6.67 | short |
| y-y (about minor) | 3000 | 300 | 10.00 | short |
Both ratios are below 12, so the column is short; no additional moment is required.
Minimum eccentricity (cl. 25.4)
- About x-x: mm (min. 20 mm); adopt 21.0 mm; kN·m
- About y-y: mm (min. 20 mm); adopt 20.0 mm; kN·m
Design moments
- Design moments: kN·m, kN·m (not less than the minimum-eccentricity values).
Longitudinal reinforcement
Bars are chosen so that lies between 0.8% (minimum) and 4% (practical maximum; IS 456 cl. 26.5.3.1 allows 6%). The uniaxial capacities , at are read from the SP-16 interaction charts for rectangular sections; here they are computed by strain compatibility with the IS 456 stress block and the design stress-strain curve of steel (same basis as the charts), with effective cover .
| Trial | (%) | ||||||
|---|---|---|---|---|---|---|---|
| 16-16 φ | 2.38 | 0.124 | 204.2 | 118.9 | 0.502 | 1.50 | 1.180 ✗ |
| 12-20 φ | 2.79 | 0.129 | 229.4 | 130.4 | 0.471 | 1.45 | 1.032 ✗ |
| 8-25 φ | 2.91 | 0.134 | 238.6 | 134.3 | 0.463 | 1.44 | 0.988 ✓ |
Check
kN , so (IS 456 cl. 39.6; linear between 1.0 at 0.2 and 2.0 at 0.8).
The interaction condition is satisfied; the section is safe.
Provide 8-25 mm bars ( mm², ), within 0.8% to 4%.
Lateral ties
- Diameter mm → provide 8 mm.
- Pitch (least lateral dimension, , 300 mm) mm → provide 8 mm ties @ 300 mm c/c.
Detailing
CROSS-SECTION 300 x 450
+-------------------------+
| |
| o o o |
| |
| |
| |
| o o |
| |
| |
| |
| o o o |
| |
+-------------------------+
o = 25 mm bars, ties 8 mm @ 300 c/c
Answer: 300 × 450 mm column with 8-25 mm longitudinal bars () and 8 mm ties @ 300 mm c/c.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Short column 350x500, M30, 1500 kN · Design of RCC Structure, chapter 10 · asked 2×
- Short column 300x500, 2000 kN, M30 · Design of RCC Structure, chapter 10
- Column 350x350, 1440 kN, ductile detailing · Design of RCC Structure, chapter 10 · asked 2×
- Biaxial column 400x600, 1500 kN · Design of RCC Structure, chapter 10
- Column 650x450 in double curvature · Design of RCC Structure, chapter 10
- Column 350x550 with major axis moment · Design of RCC Structure, chapter 10
- Rectangular footing, 450x450, uniaxial moment 240 kNm · Design of RCC Structure, chapter 11
- Rectangular Sal column, 150 kN + 15 kNm · Design of Steel and Timber Structure, chapter 11
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Corner stresses of 450 x 750 column (150 kN) · Concrete Technology and Masonry Structure, chapter 8
- Built-up column, battens, 6 m unsupported, 1200 kN · Design of Steel and Timber Structure, chapter 6