Motor adjustment to load and excitation effects

Short answer

When load increases, rotor angle δ grows while speed stays synchronous, increasing armature current to match load; beyond δ=90° it pulls out. Changing excitation at constant load varies armature current and pf: under-excited gives lagging pf, normal gives minimum current unity pf, over-excited gives leading pf (synchronous condenser).

Explain how synchronous motor adjust itself for the change in load. Elaborate the effects of change in excitation of synchronous motor on armature current and power factor with proper diagram.

A synchronous motor always runs at synchronous speed Ns=120f/PN_s = 120f/P. When the shaft load changes it cannot slow down (as an induction motor does); instead the rotor shifts backwards in space by a larger load angle δ\delta, and the armature current changes to supply the new power.

Adjustment to change in load

  1. At no load the rotor poles are almost in line with the stator field (δ≈0\delta \approx 0), and the motor draws only enough current to meet losses.
  2. When load torque increases, the rotor momentarily slows down. The rotor poles fall back with respect to the rotating stator field, so δ\delta increases.
  3. Back emf EfE_f stays the same in magnitude (excitation unchanged) but moves further behind VV. The resultant voltage Er=V−EfE_r = V - E_f grows, so armature current Ia=Er/jXsI_a = E_r / jX_s increases.
  4. Power drawn P=3VEfXssin⁡δP = \dfrac{3VE_f}{X_s}\sin\delta rises until it equals the new load plus losses. The rotor then runs again at NsN_s with a larger fixed δ\delta.
  5. If load exceeds PmaxP_{max} (at δ=90∘\delta = 90^\circ for a cylindrical rotor), the motor pulls out of step and stops.
          V (fixed)
   ------------------>
     \  delta1
      \--------> Ef (light load)
       \
        \ delta2 > delta1
         \------> Ef (heavy load, same length)

Effect of change in excitation (constant load)

With load (and hence P=VIacos⁡ϕP = VI_a\cos\phi) constant, Iacos⁡ϕI_a\cos\phi is constant, so the tip of IaI_a moves on a line perpendicular to VV, and Efsin⁡δE_f\sin\delta is also constant.

ExcitationEfE_f vs VVArmature currentPower factor
Under-excitedEf<VE_f < VLargeLagging
NormalEf≈VE_f \approx VMinimumUnity
Over-excitedEf>VE_f > VLargeLeading
           I(lead)   I(unity)
             \         |
              \        |
  ------------ +-------+--------> V
                \      |
             I(lag)  locus of I tip
                      (I cos(phi) const)
  • Raising the field current from a low value first reduces IaI_a (lagging pf improves) until IaI_a is minimum at unity pf.
  • Further increase makes IaI_a rise again with a leading pf.
  • Plotting IaI_a against field current gives the V-curves; the pf vs field current curve is an inverted V.

This is why an over-excited synchronous motor can act as a synchronous condenser to improve plant power factor.