Synchronous motor adjusting to increasing load

Short answer

Increasing shaft load momentarily slows the rotor, increasing the load angle δ between rotor and stator fields. This raises armature current and developed power (P ∝ sinδ) until torque balances, maintaining synchronous speed. The limit is the pull-out torque at δ=90°.

In what manner does a synchronous motor adjust itself to an increasing shaft load?

A synchronous motor meets an increasing shaft load without changing speed. It does so by increasing its load (torque) angle δ\delta, the angle by which the rotor poles (and EfE_f) fall behind the stator field (and VV).

Step-by-step action

  1. At no load, the rotor poles are almost exactly under the stator poles; δ\delta is very small and the motor draws only a small current for losses.
  2. Load is increased. Load torque becomes greater than the developed torque, so the rotor decelerates momentarily.
  3. Rotor falls back. Because the stator field keeps rotating at NsN_s, the rotor poles slip back by a larger angle δ\delta. The magnetic "spring" linking the poles is stretched more.
  4. More current. EfE_f keeps the same magnitude (field current unchanged) but swings further behind VV. The resultant voltage Er=V−EfE_r = V - E_f increases, so Ia=Er/XsI_a = E_r/X_s increases.
  5. More power. Developed power rises:
P=3VEfXssin⁡δP = \frac{3VE_f}{X_s}\sin\delta
  1. New balance. When the developed torque equals load torque plus losses, the rotor again runs at exactly NsN_s, but with a larger fixed δ\delta.
  V ------------------------------>
   \ \
    \  \  delta2 (more load)
     \   \
      \    '----> Ef2  (same length)
  delta1
       '---------> Ef1 (light load)

  Er2 > Er1  ->  Ia2 > Ia1

Limit of loading

  • Power rises with δ\delta only up to δ=90∘\delta = 90^\circ (cylindrical rotor), where Pmax=3VEf/XsP_{max} = 3VE_f/X_s.
  • If load is increased beyond this pull-out torque, the rotor cannot stay locked; it falls out of step, and the motor stalls with heavy current (the protection then trips).
  • The pull-out limit can be raised by increasing excitation (EfE_f).

Other effects

  • With fixed excitation, the power factor changes with load; for a given EfE_f the pf moves towards lagging as load increases.
  • A sudden load change makes the rotor overshoot and oscillate about the new δ\delta (hunting); damper windings reduce this.