Design pipes PQ, PR and RS, C = 110

Short answer

Use Hazen-Williams equation with C=110. Pipe PQ (0.25 lps, 180 m) adopts 25 mm, pipe PR (0.7 lps, 150 m) adopts 20 mm, pipe RS (0.3 lps, 160 m) adopts 20 mm. Residual heads exceed 10 m at all taps.

Design pipes PQ, PR and RS. Minimum pressures have to be maintained at 1 kg/cm2^2 in all taps. Take Hazen William constant C = 110.

[Figure: Source at P, RL of source = 950 m. Pipe PR, length 150 m, carries 0.7 lps to R (RL 860 m, Tap 1); from R, pipe RS, length 160 m, carries 0.3 lps to S (RL 845 m, Tap 2); pipe PQ, length 180 m, carries 0.25 lps to Q (RL 930 m, Tap 3).]

Residual pressure = 1 kg/cm² = 10 m at all taps; C = 110. HGL at source P = 950 m. The flows given for each pipe are taken as the discharge carried by that pipe (PR = 0.7 lps, RS = 0.3 lps, PQ = 0.25 lps).

Method

Use the Hazen-Williams equation in SI units:

hf=10.67 L Q1.852C1.852D4.87h_f = \frac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}

with QQ in m³/s, LL and DD in m. For each pipe the available head is (HGL at upstream end − ground RL of the tap − required residual head). The gradient S=H/LS = H/L gives the calculated diameter, the next larger commercial size is adopted, and the real head loss and residual head are then checked. Commercial sizes (nominal bore): 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mm and so on. Constant C = 110.

Pipe PR

  • Discharge Q=0.700Q = 0.700 lps, length L=150L = 150 m
  • HGL at P = 950.00 m; ground RL at R = 860 m; residual head required = 10 m
  • Available head H=950.00−860−10=80.00H = 950.00 - 860 - 10 = 80.00 m
  • Gradient S=H/L=80.00/150=0.53333S = H/L = 80.00/150 = 0.53333
  • From hf=10.67 L Q1.852C1.852D4.87h_f = \dfrac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}: Dcalc=19.5D_{calc} = 19.5 mm, adopt commercial size 20 mm
  • Actual hf=71.565h_f = 71.565 m, HGL at R = 878.43 m, residual head = 18.43 m (≥ 10 m, OK)
  • Velocity v=Q/A=2.23v = Q/A = 2.23 m/s

Pipe RS

  • Discharge Q=0.300Q = 0.300 lps, length L=160L = 160 m
  • HGL at R = 878.43 m; ground RL at S = 845 m; residual head required = 10 m
  • Available head H=878.43−845−10=23.43H = 878.43 - 845 - 10 = 23.43 m
  • Gradient S=H/L=23.43/160=0.14647S = H/L = 23.43/160 = 0.14647
  • From hf=10.67 L Q1.852C1.852D4.87h_f = \dfrac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}: Dcalc=18.5D_{calc} = 18.5 mm, adopt commercial size 20 mm
  • Actual hf=15.894h_f = 15.894 m, HGL at S = 862.54 m, residual head = 17.54 m (≥ 10 m, OK)
  • Velocity v=Q/A=0.95v = Q/A = 0.95 m/s

Pipe PQ

  • Discharge Q=0.250Q = 0.250 lps, length L=180L = 180 m
  • HGL at P = 950.00 m; ground RL at Q = 930 m; residual head required = 10 m
  • Available head H=950.00−930−10=10.00H = 950.00 - 930 - 10 = 10.00 m
  • Gradient S=H/L=10.00/180=0.05556S = H/L = 10.00/180 = 0.05556
  • From hf=10.67 L Q1.852C1.852D4.87h_f = \dfrac{10.67\,L\,Q^{1.852}}{C^{1.852}D^{4.87}}: Dcalc=21.0D_{calc} = 21.0 mm, adopt commercial size 25 mm
  • Actual hf=4.303h_f = 4.303 m, HGL at Q = 945.70 m, residual head = 15.70 m (≥ 10 m, OK)
  • Velocity v=Q/A=0.51v = Q/A = 0.51 m/s

Summary

PipeQ (lps)L (m)Calc. D (mm)Adopted D (mm)h_f (m)Residual (m)v (m/s)
PR0.715019.52071.5718.432.23
RS0.316018.52015.8917.540.95
PQ0.2518021.0254.3015.700.51

Static heads: Q = 950 − 930 = 20 m, R = 90 m, S = 105 m. Pipes PR and RS must therefore be of a class for at least 105 m; if the high pressure is a problem, a break pressure tank can be provided near R.

Answer: PQ = 25 mm, PR = 20 mm, RS = 20 mm. (Velocity in PR is 2.23 m/s, still within the 3 m/s limit.)