- 2080 Chaitra · 8 marks
Pelton turbine design (5 m³/s, 312.5 m)
Short answer
Single-jet Pelton wheel: power 13.03 MW at 200 rpm (30 poles). Jet diameter 288 mm, wheel diameter 3.44 m, jet ratio 11.94. Specific speed 17.4. 21 buckets; bucket width 1.44 m, depth 0.35 m.
Design of a Pelton turbine for a hydropower plant having net head of 312.5 m and discharge 5 cumecs. Take efficiency of turbine 85%, frequency 50 Hz and velocity coefficient 0.98.
A Pelton wheel is designed by finding the jet velocity and jet diameter, choosing a synchronous speed that gives a suitable jet ratio (10 to 14 for good efficiency), and then sizing the wheel and buckets.
Data: m³/s, m, , Hz, coefficient of velocity of the jet (given). Assumed from the standard range: speed ratio (0.43 to 0.47).
1. Power developed
2. Jet velocity and bucket (peripheral) velocity
3. Jet diameter (single jet)
4. Speed of the wheel
Trial with jet ratio : m, so
Nearest synchronous speed for 50 Hz: rpm (30 poles).
5. Wheel (pitch circle) diameter and jet ratio
lies within 10 to 14, so a single-jet wheel is satisfactory.
6. Specific speed check
This is within the single-jet Pelton range (about 8.5 to 30), so the Pelton wheel is the correct choice.
7. Number of buckets (Tygun's formula)
8. Bucket size (usual proportions)
- Bucket width m
- Bucket depth m
- Bucket radial length m
Summary of design
| Item | Value |
|---|---|
| Power | 13.03 MW |
| Speed | 200 rpm |
| Number of jets | 1 |
| Jet diameter | 288 mm |
| Wheel diameter | 3.44 m |
| Jet ratio | 11.94 |
| Specific speed | 17.4 |
| Number of buckets | 21 |
| Bucket width × depth | 1.44 m × 0.35 m |
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Pelton turbine design (5 m³/s, 310 m) · Hydro Power, chapter 7
- Pelton turbine design (2 m³/s, 500 m) · Hydro Power, chapter 7 · asked 2×
- Pelton turbine design (3.75 m³/s, 380 m) · Hydro Power, chapter 7
- Pelton turbine design (1.8 m³/s, 605 m) · Hydro Power, chapter 7 · asked 2×
- Pelton turbine design (2 m³/s, 605 m, Ns 100) · Hydro Power, chapter 7
- Francis turbine design (55 m³/s, 25 m) · Hydro Power, chapter 7
- Pelton turbine design (312.5 m, 5 m³/s) · Hydropower Engineering, chapter 7
- Design: 300 m head plant, GCB rating · Power Plant Design, chapter 4 · asked 11×
- Pelton turbine design (6867 kW, 350 m) · Hydropower Engineering, chapter 7
- Design: 230 m head plant, 55 km line · Power Plant Design, chapter 4 · asked 12×