- 2079 Baisakh · 12 marks
Footing for 400x300 column, reversible moment
Short answer
Provide a 3.6 m × 1.8 m footing, 800 mm deep, with identical top and bottom steel. Along the length, use 16 mm bars @ 150 mm c/c; along the width, central band with 12 bars of 16 mm @ 150 mm c/c and each outer strip with 5 bars of 16 mm @ 180 mm c/c.
Design a RC footing for a column having x-sectional dimension 400 mm x 300 mm, with 8-16 longitudinal reinforcement, column is subjected to axial compressive load of 1000 kN and reversible bending moment 100 kNm. Consider M20 concrete for footing, M25 concrete for column and Fe415 steel grade for both. Take safe bearing capacity of soil is 200 kN/m at a depth at 1.5 m.
Data and assumptions
- Column 400 mm × 300 mm (long side mm along the footing length); footing concrete M20, steel Fe415; column concrete M25; column bars 8-16 mm.
- Service load kN, service moment kN·m.
- Allowable (safe) bearing capacity of soil = 200 kN/m² at 1.5 m depth.
- Loads are service loads. The moment is reversible, so the same steel is provided on both sides.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth mm (cover + half bar). Load factor 1.5.
Size of footing
Weight of footing and backfill is taken as 10% of the column load.
Eccentricity m, which is less than , so there is no tension under the base. The size is chosen so that
Try m ( m²): kN/m² and kN/m² . Safe.
Factored soil pressure
kN, kN·m. : kN/m², kN/m² (average 231.5 kN/m²). Self-weight does not cause bending in the footing, so it is excluded.
Bending moments and reinforcement
Cantilever projections from the column face: along : mm; along : mm. Along (critical section at the column face on the side of maximum pressure, linear pressure): , with kN/m² at the face and m: kN·m. Along (average pressure): kN·m. Required depth for flexure: is far larger than the moment for mm, so the depth is governed by shear (one-way or punching). Trial mm, mm, found by the shear checks below.
; minimum steel = 0.12% of .
| Direction | (kN·m) | req (mm²) | Provide | prov (mm²) |
|---|---|---|---|---|
| Along (width ) | 595.9 | 2315 | 16 mm @ 150 c/c | 2413 |
| Along (width ) | 234.4 | 3456 | 16 mm @ 205 c/c | 3531 |
For the rectangular footing, the short-direction steel is placed in a central band of width mm in the proportion (IS 456 cl. 34.3.1), where .
- Central band: mm² → 16 mm @ 150 mm c/c (12 bars).
- Each outer strip (900 mm wide): remaining steel 576 mm² or minimum 0.12% = 864 mm², whichever is more → 16 mm @ 180 mm c/c (5 bars).
Check for one-way shear (at distance from the column face)
- Along side: kN, MPa; , MPa (IS 456 Table 19, SP 16 formula). , safe.
- Along side: kN, MPa; , MPa. Safe.
Check for two-way (punching) shear (at from the column face)
- Perimeter mm
- kN (average pressure; the effect of moment transfer is neglected).
- MPa; , MPa. , safe.
Development length
, MPa (M20, deformed bars): 16 mm bars (both directions) → mm. Available length from column face (less 50 mm end cover): 1550 mm along (adequate), 700 mm along . Along the available 700 mm is slightly less than mm, so the bars are given 90° bends at the ends (each bend adds an anchorage value of mm), which is adequate.
Bearing stress and transfer of load from column
Column area m². Bearing stress MPa. Permissible bearing stress: column concrete MPa; footing concrete with gives up to 18.00 MPa. The lesser, 11.25 MPa, governs. Capacity of bearing = 1350 kN kN, so the excess 150 kN must be carried by dowels: mm²; the column bars (8-16 mm, 1608 mm²) are continued into the footing as dowels, which is adequate. Dowel length in compression mm (and the same lap with the column bars). Available depth in footing = 800 - 50 - 32 = 718 mm , adequate.
Detailing
PLAN ELEVATION
+------------------+ col
| # # # # # # | | |
| # +------+ # # | _|_|__
| # | col | # # | |_____| <- D = 800 mm
| # +------+ # # | bars both ways
| # # # # # # |
+------------------+
L = 3.6 m, B = 1.8 m
- Bottom mesh: 16 mm @ 150 c/c along (lower layer); along (upper layer), 16 mm @ 150 c/c in the central 1.8 m band and 16 mm @ 180 c/c in each outer strip, 50 mm clear cover; dowels 8-16 mm.
Answer: Footing 3.6 m × 1.8 m × 800 mm thick; 16 mm @ 150 c/c along the length; along the width, 16 mm @ 150 c/c in the central 1.8 m band and 16 mm @ 180 c/c in the outer strips.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Footing 350x350, 8-16 mm bars, reversible moment · Design of RCC Structure, chapter 11
- Footing with load transfer check, 1000 kN · Design of RCC Structure, chapter 11
- RC wall footing, 1000 kN total load · Design of RCC Structure, chapter 11
- Footing, 1250 kN column load, depth 1.8 m · Design of RCC Structure, chapter 11
- Fixed-end column 4 m, 1000 kN · Design of RCC Structure, chapter 10
- Footing 300x400 column, factored moment 120 kNm · Design of RCC Structure, chapter 11
- Timber column under axial load and bending · Design of Timber and Masonry Structures, chapter 3
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Built-up column with battens, 4 m, 1000 kN · Design of Steel and Timber Structure, chapter 6 · asked 2×
- Safe axial load on a timber column · Design of Timber and Masonry Structures, chapter 3