Isolated square footing, 650 kN service

Short answer

Provide a 2.1 m square footing, 450 mm thick. Reinforcement: 12 mm bars @ 205 mm c/c both ways. Provide 8 dowels of 16 mm diameter.

Design an isolated square footing foundation of uniform thickness for a 400 mm x 400 mm column subjected to an axial load of 650 kN at service state. Consider safe bearing capacity of soil as 170 kN/m2^2 and concrete of M20 and steel grade of Fe500. Show the reinforcements in plan and in section of footing.

Data and assumptions

  • Column 400 mm × 400 mm (long side a=400a=400 mm along the footing length); footing concrete M20, steel Fe500; column concrete M20; column bars 8-16 mm.
  • Service load P=650P = 650 kN.
  • Allowable (safe) bearing capacity of soil = 170 kN/m².
  • Column bars assumed 8-16 mm.
  • Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth d=D−60d = D - 60 mm (cover + half bar). Load factor 1.5.

Size of footing

Weight of footing and backfill is taken as 10% of the column load.

Areq=1.1 Pqa=1.1×650.0170=4.21 m2A_{req} = \frac{1.1\,P}{q_a} = \frac{1.1 \times 650.0}{170} = 4.21\ \text{m}^2

Provide a square footing L×B=2.1×2.1L \times B = 2.1 \times 2.1 m, area = 4.41 m² ≥\ge 4.21 m².

Factored soil pressure

Pu=1.5×650.0=975.0P_u = 1.5 \times 650.0 = 975.0 kN. pu=PuBL=975.02.1×2.1=221.1p_u = \dfrac{P_u}{BL} = \dfrac{975.0}{2.1 \times 2.1} = 221.1 kN/m².

Bending moments and reinforcement

Cantilever projections from the column face: along LL: (2100−400)/2=850(2100 - 400)/2 = 850 mm; along BB: (2100−400)/2=850(2100 - 400)/2 = 850 mm. Mu=pu×(width)×(projection)22M_u = p_u \times (\text{width}) \times \dfrac{(\text{projection})^2}{2}: Mu,L=167.7M_{u,L} = 167.7 kN·m, Mu,B=167.7M_{u,B} = 167.7 kN·m. Required depth for flexure: Mu,lim=0.133fckbd2M_{u,lim} = 0.133 f_{ck} b d^2 is far larger than the moment for d=390d = 390 mm, so the depth is governed by shear (one-way or punching). Trial D=450D = 450 mm, d=390d = 390 mm, found by the shear checks below.

Ast=0.5fckfy[1−1−4.6Mufckbd2]bdA_{st} = \dfrac{0.5 f_{ck}}{f_y}\left[1 - \sqrt{1 - \dfrac{4.6 M_u}{f_{ck} b d^2}}\right] b d; minimum steel = 0.12% of bDbD.

DirectionMuM_u (kN·m)AstA_{st} req (mm²)ProvideAstA_{st} prov (mm²)
Along LL (width BB)167.7113412 mm @ 205 c/c1159
Along BB (width LL)167.7113412 mm @ 205 c/c1159

Check for one-way shear (at distance dd from the column face)

  • Along LL side: Vu=213.6V_u = 213.6 kN, τv=VuBd=0.261\tau_v = \dfrac{V_u}{B d} = 0.261 MPa; pt=0.141%p_t = 0.141\%, τc=0.288\tau_c = 0.288 MPa (IS 456 Table 19, SP 16 formula). τv<τc\tau_v < \tau_c, safe.
  • Along BB side: Vu=213.6V_u = 213.6 kN, τv=0.261\tau_v = 0.261 MPa; pt=0.141%p_t = 0.141\%, τc=0.288\tau_c = 0.288 MPa. Safe.

Check for two-way (punching) shear (at d/2d/2 from the column face)

  • Perimeter bo=2[(a+d)+(c+d)]=2[(400+390)+(400+390)]=3160b_o = 2[(a + d) + (c + d)] = 2[(400+390) + (400+390)] = 3160 mm
  • Vu=Pu−pu(a+d)(c+d)=975.0−221.1×0.790×0.790=837.0V_u = P_u - p_u (a+d)(c+d) = 975.0 - 221.1 \times 0.790 \times 0.790 = 837.0 kN (average pressure; the effect of moment transfer is neglected).
  • τv=Vubod=0.679\tau_v = \dfrac{V_u}{b_o d} = 0.679 MPa; ks=0.5+βc=1.00k_s = 0.5 + \beta_c = 1.00, τc′=ks×0.25fck=1.118\tau_c' = k_s \times 0.25\sqrt{f_{ck}} = 1.118 MPa. τv<τc′\tau_v < \tau_c', safe.

Development length

Ld=0.87fyϕ4τbdL_d = \dfrac{0.87 f_y \phi}{4\tau_{bd}}, τbd=1.92\tau_{bd} = 1.92 MPa (M20, deformed bars): 12 mm bars (both directions) → Ld=680L_d = 680 mm. Available length from column face (less 50 mm end cover): 800 mm along LL, 800 mm along BB. Satisfied in both directions.

Bearing stress and transfer of load from column

Column area A2=400×400=0.160A_2 = 400\times400 = 0.160 m². Bearing stress =Pu/A2=6.09= P_u/A_2 = 6.09 MPa. Permissible bearing stress: column concrete 0.45fck=9.000.45 f_{ck} = 9.00 MPa; footing concrete 0.45fckA1/A20.45 f_{ck}\sqrt{A_1/A_2} with A1/A2≤2\sqrt{A_1/A_2} \le 2 gives up to 18.00 MPa. The lesser, 9.00 MPa, governs. Capacity of bearing = 1440 kN ≥\ge Pu=975P_u = 975 kN, so the whole load can be transferred by bearing. Provide minimum dowels of 0.5% of column area = 800 mm²: use 8 bars of 16 mm (1608 mm²) as dowels, same as column bars. Dowel length in compression Ldc=0.87fyϕ4×1.25 τbd=725L_{dc} = \dfrac{0.87 f_y\phi}{4 \times 1.25\,\tau_{bd}} = 725 mm (and the same lap with the column bars). Available depth in footing = 450 - 50 - 24 = 376 mm <Ldc< L_{dc}; dowels are bent at the bottom with 90° bends.

Detailing

PLAN                      ELEVATION
+------------------+      col
| #  #  #  #  #  # |      | |
| #  +------+  #  # |     _|_|__
| #  | col  |  #  # |    |_____|  <- D = 450 mm
| #  +------+  #  # |    bars both ways
| #  #  #  #  #  # |
+------------------+
 L = 2.1 m, B = 2.1 m
  • Bottom mesh: 12 mm @ 205 c/c along LL (lower layer), 12 mm @ 205 c/c along BB (upper layer), 50 mm clear cover; dowels 8-16 mm.

Answer: Footing 2.1 m × 2.1 m × 450 mm thick; 12 mm @ 205 c/c along the length and 12 mm @ 205 c/c along the width.