- Asked 2/25
- 2082 Baisakh · 12 marks
Isolated footing 450x450, service moment 110 kNm
Short answer
Use a 4.0 m x 2.3 m footing, overall depth 700 mm (d=640 mm). Provide 16 mm bars @150 mm c/c along the longer direction; in the short direction, place a central band of 12 mm bars @100 mm c/c and outer strips of 12 mm @120 mm c/c. One-way and two-way shear are safe.
Design an isolated footing for a column of size 450 mm x 450 mm with 8-20 mm diameter bars as longitudinal reinforcement in order to carry a service axial load of 1000 kN and service moment of 110 kNm. Take the safe bearing capacity of soil as 140 kN/m. Use M20 concrete and Fe 415 steel.
Data and assumptions
- Column 450 mm × 450 mm (long side mm along the footing length); footing concrete M20, steel Fe415; column concrete M20; column bars 8-20 mm.
- Service load kN, service moment kN·m.
- Allowable (safe) bearing capacity of soil = 140 kN/m².
- The service moment acts about one axis.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth mm (cover + half bar). Load factor 1.5.
Size of footing
Weight of footing and backfill is taken as 10% of the column load.
Eccentricity m, which is less than , so there is no tension under the base. The size is chosen so that
Try m ( m²): kN/m² and kN/m² . Safe.
Factored soil pressure
kN, kN·m. : kN/m², kN/m² (average 163.0 kN/m²). Self-weight does not cause bending in the footing, so it is excluded.
Bending moments and reinforcement
Cantilever projections from the column face: along : mm; along : mm. Along (critical section at the column face on the side of maximum pressure): the pressure is 166.1 kN/m² at the face and 189.9 kN/m² at the edge, so per metre width kN·m/m, and kN·m. Along (average pressure): kN·m. Required depth for flexure: is far larger than the moment for mm, so the depth is governed by shear (one-way or punching). Trial mm, mm, found by the shear checks below.
; minimum steel = 0.12% of .
| Direction | (kN·m) | req (mm²) | Provide | prov (mm²) |
|---|---|---|---|---|
| Along (width ) | 659.3 | 2980 | 16 mm @ 150 c/c | 3083 |
| Along (width ) | 279.0 | 3360 (minimum) | 12 mm, banded (below) | 4184 |
For the rectangular footing, the short-direction steel is placed in a central band of width mm in the proportion (IS 456 cl. 34.3.1), where .
- Central band: mm² → 12 mm @ 100 mm c/c (23 bars, 2601 mm²).
- Each outer strip (850 mm wide): remaining steel 453 mm² or minimum 0.12% = 714 mm², whichever is more → 12 mm @ 120 mm c/c (7 bars, 792 mm²).
Check for one-way shear (at distance from the column face)
- Along side: kN, MPa; , MPa (Table 19). , safe.
- Along side: kN, MPa; , MPa. Safe.
Check for two-way (punching) shear (at from the column face)
- Perimeter mm
- kN (average pressure; the effect of moment transfer is neglected).
- MPa; , MPa. , safe.
Development length
, MPa (M20, deformed bars): 16 mm bars → mm; 12 mm bars → mm. Available length from column face (less 50 mm end cover): 1725 mm along , 875 mm along . Satisfied in both directions.
Bearing stress and transfer of load from column
Column area m². Bearing stress MPa. Permissible bearing stress: column concrete MPa; footing concrete with gives up to 18.00 MPa. The lesser, 9.00 MPa, governs. Capacity of bearing = 1822 kN kN, so the whole load can be transferred by bearing. Provide minimum dowels of 0.5% of column area = 1012 mm²: use 8 bars of 20 mm (2513 mm²) as dowels, same as column bars. Dowel length in compression mm (and the same lap with the column bars). Available depth in footing = 700 - 50 - 28 = 622 mm ; dowels are bent at the bottom with 90° bends.
Detailing
PLAN (4.0 m x 2.3 m; L horizontal)
+--------------------------------------------+
| | | | | | | | | | | | |
|--+---+---+---+---+---+---+---+---+---+---+-|
| | | | | | | | | | | | |
|--+---+---+---+-+----------+--+---+---+---+-|
| | | | | | column | | | | | |
|--+---+---+---+-+----------+--+---+---+---+-|
| | | | | | | | | | | | |
|--+---+---+---+---+---+---+---+---+---+---+-|
| | | | | | | | | | | | |
+--------------------------------------------+
<-0.85 m><---central band 2.3 m---><-0.85 m>
- = 16 mm @ 150 c/c (along L)
| = 12 mm along B: @ 100 c/c in central band, @ 120 c/c in outer strips
ELEVATION
| column |
| |
+----------------+----------+----------------+
| (dowels) | D = 700 mm
| o o o o o o o o o o o o o o | bottom mesh, 50 mm cover
+--------------------------------------------+
<----------------- 4000 mm ------------------>
- Bottom mesh: 16 mm @ 150 c/c along (lower layer); along (upper layer), 12 mm @ 100 c/c in the central 2.3 m band and 12 mm @ 120 c/c in each 0.85 m outer strip; 50 mm clear cover; dowels 8-20 mm.
Answer: Footing 4.0 m × 2.3 m × 700 mm thick; 16 mm @ 150 c/c along the length; along the width, 12 mm @ 100 c/c in the central 2.3 m band and 12 mm @ 120 c/c in the outer strips.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Isolated footing 400x400, service moment 120 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Isolated footing 450x450, 1600 kN service · Design of RCC Structure, chapter 11
- Rectangular footing, 450x450, uniaxial moment 240 kNm · Design of RCC Structure, chapter 11
- Footing with load transfer check, 1000 kN · Design of RCC Structure, chapter 11
- Isolated square footing, 600 kN and 50 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Footing, 450x500 column, 6#20, uniaxial moment · Design of RCC Structure, chapter 11
- Footing 300x400 column, factored moment 120 kNm · Design of RCC Structure, chapter 11
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Check 25 cm x 25 cm Sal column, 200 kN + 20 kNm · Design of Steel and Timber Structure, chapter 11
- Timber column under axial load and bending · Design of Timber and Masonry Structures, chapter 3
- Select Sal column, 200 kN + 30 kNm · Design of Steel and Timber Structure, chapter 11