Skip to main content

Rectangular footing, 600x600 column, 1150 kN

Short answer

Footing size 4.0 m × 2.2 m, 850 mm deep. Longitudinal steel 16 mm @ 155 mm c/c; transverse steel central band 16 mm @ 145 mm c/c and outer strips 16 mm @ 175 mm c/c.

Design a rectangle footing to carry a column load of 1150 kN and BM of 250 kN-m from 600 x 600 mm square column with the 20 mm diameter steel. The bearing capacity of soil is 200 kN/m2^2. Consider depth of foundation as 1.5 m. Take unit weight of earth is 17 kN/m3^3. Use M20 concrete and Fe 415 steel.

Data and assumptions

  • Column 600 mm × 600 mm (long side a=600a=600 mm along the footing length); footing concrete M20, steel Fe415; column concrete M20; column bars 8-20 mm.
  • Service load P=1150P = 1150 kN, service moment M=250M = 250 kN·m.
  • Allowable (safe) bearing capacity of soil = 200 kN/m² at 1.5 m depth, soil unit weight 17 kN/m³.
  • Loads are service loads.
  • Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth d=D−60d = D - 60 mm (cover + half bar). Load factor 1.5.

Size of footing

Net safe bearing capacity = q−γDf=200−17×1.5=174.50q - \gamma D_f = 200 - 17 \times 1.5 = 174.50 kN/m² (this takes care of the weight of footing and backfill).

Areq=Pqnet=1150.0174.50=6.59 m2A_{req} = \frac{P}{q_{net}} = \frac{1150.0}{174.50} = 6.59\ \text{m}^2

Eccentricity e=M/P=250.0/1150.0=0.217e = M/P = 250.0/1150.0 = 0.217 m, which is less than L/6L/6, so there is no tension under the base. The size is chosen so that

qmax=PBL(1+6eL)≤qaq_{max} = \frac{P}{BL}\left(1 + \frac{6e}{L}\right) \le q_a

Try L×B=4.0×2.2L \times B = 4.0 \times 2.2 m (A=8.80A = 8.80 m²): qmax=173.3q_{max} = 173.3 kN/m² ≤174.5\le 174.5 and qmin=88.1q_{min} = 88.1 kN/m² >0> 0. Safe.

Factored soil pressure

Pu=1.5×1150.0=1725.0P_u = 1.5 \times 1150.0 = 1725.0 kN, Mu=375.0M_u = 375.0 kN·m. pu=PuBL(1±6eL)p_u = \dfrac{P_u}{BL}\left(1 \pm \dfrac{6e}{L}\right): pu,max=259.9p_{u,max} = 259.9 kN/m², pu,min=132.1p_{u,min} = 132.1 kN/m² (average 196.0 kN/m²). Self-weight does not cause bending in the footing, so it is excluded.

Bending moments and reinforcement

Cantilever projections from the column face: along LL: (4000−600)/2=1700(4000 - 600)/2 = 1700 mm; along BB: (2200−600)/2=800(2200 - 600)/2 = 800 mm. Along LL (critical section at the column face on the side of maximum pressure, linear pressure): Mu,L=B[pfx22+(pmax−pf)x23]M_{u,L} = B\left[p_f\dfrac{x^2}{2} + (p_{max}-p_f)\dfrac{x^2}{3}\right], with pf=205.6p_f = 205.6 kN/m² at the face and x=1.7x = 1.7 m: Mu,L=768.8M_{u,L} = 768.8 kN·m. Along BB (average pressure): Mu,B=250.9M_{u,B} = 250.9 kN·m. Required depth for flexure: Mu,lim=0.138fckbd2M_{u,lim} = 0.138 f_{ck} b d^2 is far larger than the moment for d=790d = 790 mm, so the depth is governed by shear (one-way or punching). Trial D=850D = 850 mm, d=790d = 790 mm, found by the shear checks below.

Ast=0.5fckfy[1−1−4.6Mufckbd2]bdA_{st} = \dfrac{0.5 f_{ck}}{f_y}\left[1 - \sqrt{1 - \dfrac{4.6 M_u}{f_{ck} b d^2}}\right] b d; minimum steel = 0.12% of bDbD.

DirectionMuM_u (kN·m)AstA_{st} req (mm²)ProvideAstA_{st} prov (mm²)
Along LL (width BB)768.8279016 mm @ 155 c/c2854
Along BB (width LL)250.9408016 mm @ 195 c/c4124

For the rectangular footing, the short-direction steel is placed in a central band of width B=2200B = 2200 mm in the proportion 2β+1=21.82+1=0.710\dfrac{2}{\beta+1} = \dfrac{2}{1.82+1} = 0.710 (IS 456 cl. 34.3.1), where β=L/B\beta = L/B.

  • Central band: 0.710×4080=28950.710 \times 4080 = 2895 mm² → 16 mm @ 145 mm c/c (15 bars).
  • Each outer strip (900 mm wide): remaining steel 592 mm² or minimum 0.12% = 918 mm², whichever is more → 16 mm @ 175 mm c/c (5 bars).

Check for one-way shear (at distance dd from the column face)

  • Along LL side: Vu=491.3V_u = 491.3 kN, τv=VuBd=0.283\tau_v = \dfrac{V_u}{B d} = 0.283 MPa; pt=0.164%p_t = 0.164\%, τc=0.299\tau_c = 0.299 MPa (IS 456 Table 19, SP 16 formula). τv<τc\tau_v < \tau_c, safe.
  • Along BB side: Vu=7.8V_u = 7.8 kN, τv=0.002\tau_v = 0.002 MPa; pt=0.131%p_t = 0.131\%, τc=0.288\tau_c = 0.288 MPa. Safe.

Check for two-way (punching) shear (at d/2d/2 from the column face)

  • Perimeter bo=2[(a+d)+(c+d)]=2[(600+790)+(600+790)]=5560b_o = 2[(a + d) + (c + d)] = 2[(600+790) + (600+790)] = 5560 mm
  • Vu=Pu−pu(a+d)(c+d)=1725.0−196.0×1.390×1.390=1346.3V_u = P_u - p_u (a+d)(c+d) = 1725.0 - 196.0 \times 1.390 \times 1.390 = 1346.3 kN (average pressure; the effect of moment transfer is neglected).
  • τv=Vubod=0.306\tau_v = \dfrac{V_u}{b_o d} = 0.306 MPa; ks=0.5+βc=1.00k_s = 0.5 + \beta_c = 1.00, τc′=ks×0.25fck=1.118\tau_c' = k_s \times 0.25\sqrt{f_{ck}} = 1.118 MPa. τv<τc′\tau_v < \tau_c', safe.

Development length

Ld=0.87fyϕ4τbdL_d = \dfrac{0.87 f_y \phi}{4\tau_{bd}}, τbd=1.92\tau_{bd} = 1.92 MPa (M20, deformed bars): 16 mm bars (both directions) → Ld=752L_d = 752 mm. Available length from column face (less 50 mm end cover): 1650 mm along LL (adequate), 750 mm along BB. Along BB the available 750 mm is slightly less than Ld=752L_d = 752 mm, so the bars are given 90° bends at the ends (each bend adds an anchorage value of 8ϕ=1288\phi = 128 mm), which is adequate.

Bearing stress and transfer of load from column

Column area A2=600×600=0.360A_2 = 600\times600 = 0.360 m². Bearing stress =Pu/A2=4.79= P_u/A_2 = 4.79 MPa. Permissible bearing stress: column concrete 0.45fck=9.000.45 f_{ck} = 9.00 MPa; footing concrete 0.45fckA1/A20.45 f_{ck}\sqrt{A_1/A_2} with A1/A2≤2\sqrt{A_1/A_2} \le 2 gives up to 18.00 MPa. The lesser, 9.00 MPa, governs. Capacity of bearing = 3240 kN ≥\ge Pu=1725P_u = 1725 kN, so the whole load can be transferred by bearing. Provide minimum dowels of 0.5% of column area = 1800 mm²: use 8 bars of 20 mm (2513 mm²) as dowels, same as column bars. Dowel length in compression Ldc=0.87fyϕ4×1.25 τbd=752L_{dc} = \dfrac{0.87 f_y\phi}{4 \times 1.25\,\tau_{bd}} = 752 mm (and the same lap with the column bars). Available depth in footing = 850 - 50 - 32 = 768 mm ≥Ldc\ge L_{dc}, adequate.

Detailing

PLAN                      ELEVATION
+------------------+      col
| #  #  #  #  #  # |      | |
| #  +------+  #  # |     _|_|__
| #  | col  |  #  # |    |_____|  <- D = 850 mm
| #  +------+  #  # |    bars both ways
| #  #  #  #  #  # |
+------------------+
 L = 4.0 m, B = 2.2 m
  • Bottom mesh: 16 mm @ 155 c/c along LL (lower layer); along BB (upper layer), 16 mm @ 145 c/c in the central 2.2 m band and 16 mm @ 175 c/c in each outer strip, 50 mm clear cover; dowels 8-20 mm.

Answer: Footing 4.0 m × 2.2 m × 850 mm thick; 16 mm @ 155 c/c along the length; along the width, 16 mm @ 145 c/c in the central 2.2 m band and 16 mm @ 175 c/c in the outer strips.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Design of RCC Structure chapter 11 questions →