- 2070 Ashad · 3 marks
Frequency of flushing of settling basin
Short answer
Deposit volume per unit water: vs = (0.40×2.0)/1325 ≈ 6.04×10⁻⁴ m³ deposit/m³ water. Storage 0.1 Vb, water to fill = 165.6 Vb, so flush every 165.6 detention times (e.g., ~27.6 h for 10‑min detention).
If you have allocated about 10% volume for sediment storage and the overall trapping efficiency of the settling basin is 40%, find out the frequency of flushing of the settling basin when the sediment concentration is 2000 ppm.
Given: sediment storage of the basin volume ; overall trap efficiency ; sediment concentration ppm kg/m³. Assumption: the settled sediment has a bulk density of kg/m³ (particle density 2650 kg/m³, packing factor 0.5).
Step 1: Volume of sediment trapped per m³ of water
Step 2: Storage volume
Step 3: Volume of water that can pass before the storage is full
Step 4: Frequency of flushing
The water passes through the basin at the rate , so the time between flushes is
where is the detention time of the basin.
So the basin should be flushed once after about 165.6 detention periods (about every 166 times the time that water takes to pass through it). For example, if the detention time is 10 minutes, then minutes hours (about 0.9 flushes per day); if minutes, hours.
Answer: flush every (about 166 detention times; e.g. about 27.6 h for a 10-minute detention time).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Sediment flushing in settling basin · Hydropower Engineering, chapter 5
- Continuous flushing settling basin, 95% efficiency · Hydropower Engineering, chapter 5
- Settling basin with Hazen coefficient and sediment depth · Hydropower Engineering, chapter 5
- Settling basin 40 m³/s, 0.15 mm · Hydropower Engineering, chapter 5 · asked 4×
- Settling basin trap efficiency (Camp's diagram) · Hydropower Engineering, chapter 5
- Settling basin 60 m³/s, 0.2 mm, w = 1.5 cm/s · Hydropower Engineering, chapter 5 · asked 4×
- Settling basin design for 0.25 mm sediment · Hydro Power, chapter 5
- Ca and Mg concentration, NCH, alkalinity: TH 400 ppm · Water Supply Engineering, chapter 4
- Q and center frequency; realize −2000/(s²+500s+10⁶) · Filter Design, chapter 6
- High-volume sampler and concentration calculation · Environment and Pollution Control, chapter 1