OC and SC tests, efficiency and regulation
Short answer
OC test on LV side with HV open gives iron loss Pi and parameters Ro, Xo. SC test on HV side with LV shorted gives full-load copper loss Pcu and R₀₁, X₀₁. Efficiency η = x S cos φ / (x S cos φ + Pi + x² Pcu). % regulation ≈ (I₂ R₀₂ cos φ ± I₂ X₀₂ sin φ)/V₂ × 100.
Discuss how to conduct open-circuit and short-circuit tests on a single phase transformer. From the test results how the efficiency and voltage regulation of the transformer is determined?
Open-circuit (OC) and short-circuit (SC) tests give the core-loss and copper-loss data without loading the transformer.
Open-circuit test (no-load test)
W A
o──[W]─[A]──+───────+ o
AC V (HV winding
supply (LV side) open)
- The meters (wattmeter, ammeter, voltmeter) are connected on the low-voltage side with rated voltage V0 applied; the HV side is left open.
- Readings: V0, I0, W0. Since I0 is only 2–5 % of rated, copper loss is negligible, so W0 = iron loss Pi.
cos φ0 = W0/(V0 I0)
Iw = I0 cos φ0 , Iμ = I0 sin φ0
Ro = V0/Iw , Xo = V0/Iμ
Short-circuit test
- The HV side is supplied through a variable-voltage source (e.g. autotransformer); the LV side is short-circuited with an ammeter.
- The voltage is raised slowly until the rated current flows. This voltage is only 5–10 % of the rated voltage, so flux and iron loss are very small. Readings: Vsc, Isc, Wsc.
- Wsc = full-load copper loss Pcu.
Z01 = Vsc/Isc , R01 = Wsc/Isc² , X01 = √(Z01² − R01²)
Referring to the other side uses the factor K².
Efficiency
For a fraction x of full load at power factor cos φ:
η = x S cos φ / ( x S cos φ + Pi + x² Pcu ) × 100 %
Pi from the OC test, Pcu (at rated current) from the SC test. The load at which η is maximum is x = √(Pi/Pcu).
Regulation
Regulation = (E2 − V2)/E2 × 100 %. Using R02, X02 from the SC test and the rated secondary current I2:
% regulation ≈ (I2 R02 cos φ ± I2 X02 sin φ) / V2 × 100
"+" for lagging loads, "−" for leading loads. Maximum regulation occurs at power factor cos φ = R02/Z02.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- OC and SC tests for efficiency and regulation · Electrical Machines I, chapter 2
- OC and SC tests to build transformer equivalent circuit · Electrical Machines I, chapter 2
- OC/SC test of 2200/110 V, 40 kVA transformer · Electrical Machines I, chapter 2
- Equivalent circuit, efficiency and regulation of 5 kVA transformer · Electrical Machines I, chapter 2
- Efficiency and regulation of 5 kVA transformer · Electrical Machines I, chapter 2
- 20 kVA 250/2500 V tests, regulation, efficiency · Electrical Machines, chapter 2
- 220 kV double circuit efficiency and regulation · Transmission and Distribution System Design, chapter 4
- Design: 100 kVA 2200/480 V single phase transformer · Electric Machine Design, chapter 3 · asked 3×
- Design: 500 kVA single phase transformer with tubes · Electric Machine Design, chapter 3 · asked 2×
- 1000 VA 230/115 V transformer equivalent circuit · Electrical Machines, chapter 2