Potier method of voltage regulation
Short answer
The Potier (ZPF) method uses OCC, ZPFC and Ra. A Potier triangle is constructed from ZPFC at full-load to separate leakage reactance drop (XL = RS/I) and armature reaction mmf (SP). Regulation is found by phasor addition of V and I(Ra+jXL) to get Eg, then adding field current for Eg and armature-reaction mmf, obtaining E0 from OCC, and computing (E0-V)/V×100%.
With the help of relevant curves and diagram, explain the Potier method for determining the voltage regulation of a synchronous generator.
The Potier (zero power factor, ZPF) method finds regulation by separating the leakage reactance drop and the armature reaction mmf, and it allows for saturation. It is more accurate than the EMF and MMF methods.
Tests and curves needed
- Open-circuit characteristic (OCC): vs field current .
- Zero power factor characteristic (ZPFC): terminal voltage vs with full-load current at zero pf lagging (purely inductive load). Two points are enough: the short-circuit point A (V = 0) and one point P at rated voltage.
- Armature resistance .
Potier triangle
V OCC
| __.--''
| .-'
| .' R
| .' /| ZPFC
| .' / | __.-'
| .' / | _.-'
| / Q----S-----P (rated V,
| / rated I)
+----A---------------------> If
O (short-circuit point)
QP = OA, QR parallel to air-gap line
- From P draw PQ horizontally to the left, equal to OA.
- From Q draw a line parallel to the air-gap (linear) part of the OCC, meeting the OCC at R.
- Drop a perpendicular RS onto PQ. Triangle PRS is the Potier triangle:
- = leakage reactance drop , so (Potier reactance);
- = field current equivalent to armature reaction mmf ().
Finding regulation (phasor steps)
- Take as reference, current at the given pf.
- Air-gap emf: .
- From the OCC read the field current needed for ; it leads by 90°.
- Add the armature-reaction field current (from the triangle), drawn opposite to (to cancel the armature mmf), to : the resultant field current is , i.e. where is the angle between and (lagging pf).
- From the OCC read for . Then
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Regulation of 10 kVA round-rotor generator · Electric Machines II, chapter 1
- Regulation of 1.5 MVA generator and zero-regulation pf · Electric Machines II, chapter 1
- Salient pole generator phasor diagram in per unit · Electric Machines II, chapter 1
- Regulation and power angle of 1650 kVA generator · Electric Machines II, chapter 1
- Synchronous reactance and regulation from test data · Electric Machines II, chapter 1
- Construction and operation of synchronous generator · Electric Machines II, chapter 1
- Synchronous generator constructional diagram · Basic Electrical and Electronics Engineering, chapter 2
- Synchronous generator load characteristics, capacitive load · Electrical Machines, chapter 6
- Armature reaction in synchronous generator · Electrical Machines, chapter 6
- Reactance diagram: 20 MVA generator, 15 kV/25 MVA base · Power System Analysis I, chapter 3