Potier method of voltage regulation

Short answer

The Potier (ZPF) method uses OCC, ZPFC and Ra. A Potier triangle is constructed from ZPFC at full-load to separate leakage reactance drop (XL = RS/I) and armature reaction mmf (SP). Regulation is found by phasor addition of V and I(Ra+jXL) to get Eg, then adding field current for Eg and armature-reaction mmf, obtaining E0 from OCC, and computing (E0-V)/V×100%.

With the help of relevant curves and diagram, explain the Potier method for determining the voltage regulation of a synchronous generator.

The Potier (zero power factor, ZPF) method finds regulation by separating the leakage reactance drop and the armature reaction mmf, and it allows for saturation. It is more accurate than the EMF and MMF methods.

Tests and curves needed

  1. Open-circuit characteristic (OCC): EE vs field current IfI_f.
  2. Zero power factor characteristic (ZPFC): terminal voltage vs IfI_f with full-load current at zero pf lagging (purely inductive load). Two points are enough: the short-circuit point A (V = 0) and one point P at rated voltage.
  3. Armature resistance RaR_a.

Potier triangle

  V                        OCC
  |                  __.--''
  |               .-'
  |             .'  R
  |           .'   /|           ZPFC
  |         .'    / |        __.-'
  |       .'     /  |    _.-'
  |      /     Q----S-----P  (rated V,
  |     /                      rated I)
  +----A---------------------> If
  O  (short-circuit point)
     QP = OA, QR parallel to air-gap line
  • From P draw PQ horizontally to the left, equal to OA.
  • From Q draw a line parallel to the air-gap (linear) part of the OCC, meeting the OCC at R.
  • Drop a perpendicular RS onto PQ. Triangle PRS is the Potier triangle:
    • RSRS = leakage reactance drop IXLIX_L, so XL=RS/IX_L = RS/I (Potier reactance);
    • SPSP = field current equivalent to armature reaction mmf (FaF_a).

Finding regulation (phasor steps)

  1. Take VV as reference, current II at the given pf.
  2. Air-gap emf: Eˉg=Vˉ+Iˉ(Ra+jXL)\bar E_g = \bar V + \bar I(R_a + jX_L).
  3. From the OCC read the field current FgF_g needed for EgE_g; it leads EgE_g by 90°.
  4. Add the armature-reaction field current FaF_a (from the triangle), drawn opposite to II (to cancel the armature mmf), to FgF_g: the resultant field current is Fˉr=Fˉg+Fˉa\bar F_r = \bar F_g + \bar F_a, i.e. Fr=Fg2+Fa2+2FgFacos⁡(90∘−θ)F_r = \sqrt{F_g^2 + F_a^2 + 2F_gF_a\cos(90^\circ - \theta)} where θ\theta is the angle between EgE_g and II (lagging pf).
  5. From the OCC read E0E_0 for FrF_r. Then %Reg=E0−VV×100\%\text{Reg} = \frac{E_0 - V}{V}\times100