Regulation and power angle of 1650 kVA generator

Short answer

Per-phase Vph=7967.4 V, I=69.03 A. (a) 0.8 lagging: E=9687 V, regulation=21.58%, power angle δ=11.11°. (b) 0.8 leading: E=6902 V, regulation=−13.37%, δ=16.84°.

A three phase star-connected synchronous generator has effective resistance and synchronous reactance of 1.6 ohm and 35 ohm respectively per phase. Determine the percentage regulation and power angle for a load of 1320 kW at power factor of (a) 0.8 lagging and (b) 0.8 leading when the rating of the machine is 1650 kVA and 13.8 kV.

Given: star, 1650 kVA, 13.8 kV, Ra=1.6 ΩR_a = 1.6\ \Omega, Xs=35 ΩX_s = 35\ \Omega; load 1320 kW at 0.8 pf (= 1650 kVA, full load).

Vph=138003=7967.43 VI=1320×1033×13800×0.8=69.03 AVcos⁡ϕ+IRa=6373.95+110.45=6484.40 VVsin⁡ϕ=4780.46 V,IXs=2416.09 V\begin{aligned} V_{ph} &= \frac{13800}{\sqrt3} = 7967.43\ \text{V} \\ I &= \frac{1320\times10^3}{\sqrt3\times13800\times0.8} = 69.03\ \text{A} \\ V\cos\phi + IR_a &= 6373.95 + 110.45 = 6484.40\ \text{V} \\ V\sin\phi &= 4780.46\ \text{V},\quad IX_s = 2416.09\ \text{V} \end{aligned}

The power angle δ\delta is the angle between EE and VV. If θ\theta is the angle of EE from the current phasor, θ=tan⁡−1Vsin⁡ϕ±IXsVcos⁡ϕ+IRa\theta = \tan^{-1}\dfrac{V\sin\phi \pm IX_s}{V\cos\phi + IR_a}, then δ=θ−ϕ\delta = \theta - \phi for lagging pf and δ=ϕ−θ\delta = \phi - \theta for leading pf.

(a) 0.8 pf lagging

E=6484.402+(4780.46+2416.09)2=6484.402+7196.552=9686.98 Vθ=tan⁡−17196.556484.40=47.98∘δ=47.98∘−36.87∘=11.11∘%Reg=9686.98−7967.437967.43×100=21.58%\begin{aligned} E &= \sqrt{6484.40^2 + (4780.46 + 2416.09)^2} = \sqrt{6484.40^2 + 7196.55^2} = 9686.98\ \text{V} \\ \theta &= \tan^{-1}\frac{7196.55}{6484.40} = 47.98^\circ \\ \delta &= 47.98^\circ - 36.87^\circ = 11.11^\circ \\ \%\text{Reg} &= \frac{9686.98 - 7967.43}{7967.43}\times100 = 21.58\% \end{aligned}

(b) 0.8 pf leading

E=6484.402+(4780.46−2416.09)2=6484.402+2364.372=6902.00 Vθ=tan⁡−12364.376484.40=20.03∘δ=36.87∘−20.03∘=16.84∘%Reg=6902.00−7967.437967.43×100=−13.37%\begin{aligned} E &= \sqrt{6484.40^2 + (4780.46 - 2416.09)^2} = \sqrt{6484.40^2 + 2364.37^2} = 6902.00\ \text{V} \\ \theta &= \tan^{-1}\frac{2364.37}{6484.40} = 20.03^\circ \\ \delta &= 36.87^\circ - 20.03^\circ = 16.84^\circ \\ \%\text{Reg} &= \frac{6902.00 - 7967.43}{7967.43}\times100 = -13.37\% \end{aligned}

(In both cases EE leads VV, as it must for a generator.)

Answer: (a) regulation = 21.58%, power angle = 11.11°; (b) regulation = −13.37%, power angle = 16.84°.