- 2081 Asoj · 8 marks
Francis turbine design (45 m³/s, 150 m)
Short answer
Turbine output 56.28 MW, speed 333.33 rpm (18 poles), specific speed 150.6. Runner outlet diameter 2.13 m, inlet diameter 2.19 m, inlet height 0.28 m. Required setting is 3.22 m below tailwater.
Design a Francis turbine which is to be installed at a hydroelectric station where atmospheric pressure is 10.3 m of water and vapour pressure is 0.2 m of water. The turbine should have a design discharge of 45 m³/s, a net head of 150 meters and an efficiency of 85%.
A Francis turbine is designed by fixing its power, a synchronous speed, the specific speed and then the main runner dimensions and the safe setting (suction head) against cavitation. The empirical relations used are the standard ones of de Siervo and de Leva given in the ESHA small hydro guide.
Data: m³/s, m, , m, m of water, frequency Hz.
1. Power output
2. Trial specific speed and speed
Empirical relation for Francis turbines (metric, in kW):
3. Synchronous speed and actual specific speed
The generator must run at . The nearest synchronous speed is with poles:
This lies in the Francis range (about 50 to 450).
4. Runner outlet (throat) diameter
Peripheral velocity coefficient:
5. Runner inlet diameter and inlet height
is the height of the runner inlet, which is also the height of the guide vanes.
6. Cavitation check and setting of the turbine
Critical Thoma cavitation coefficient for Francis turbines:
Maximum suction head (height of runner outlet above tailwater):
The negative sign means the runner outlet must be placed 3.22 m below the minimum tailwater level (submerged setting) to avoid cavitation.
Summary of design
| Item | Value |
|---|---|
| Power output | 56.28 MW |
| Speed | 333.33 rpm (18 poles) |
| Specific speed | 150.6 |
| Outlet diameter | 2.13 m |
| Inlet diameter | 2.19 m |
| Inlet / guide vane height | 0.28 m |
| Thoma coefficient | 0.089 |
| Suction head | -3.22 m |
A spiral casing, 16 to 24 guide vanes and an elbow draft tube starting at diameter about complete the unit.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Francis turbine design (55 m³/s, 25 m) · Hydro Power, chapter 7
- Francis turbine design (140 m³/s, 120 m) · Hydro Power, chapter 7
- Pelton turbine design (3.75 m³/s, 380 m) · Hydro Power, chapter 7
- Pelton turbine design (2 m³/s, 500 m) · Hydro Power, chapter 7 · asked 2×
- Pelton turbine design (5 m³/s, 312.5 m) · Hydro Power, chapter 7
- Pelton turbine design (1.8 m³/s, 605 m) · Hydro Power, chapter 7 · asked 2×
- Design: 230 m head plant, 45 km line · Power Plant Design, chapter 4 · asked 12×
- Design: 150 m head plant, bus MVA levels · Power Plant Design, chapter 4 · asked 8×
- Layout of a medium head Francis station · Power Plant Design, chapter 3 · asked 2×
- Francis runner design (40 m head, 10 m³/s) · Hydropower Engineering, chapter 7