- Asked 3/34
- 2075 Bhadra · 8 marks
- 2075 Baisakh · 8 marks
- 2064 Jestha (old course) · 8 marks
Guide bund design, 4000 m3/s, f 1.1
Short answer
Using Lacey's theory: waterway W = 4.75√4000 = 300 m, upstream guide bund length 1.25W = 375 m, downstream tail 75 m. Pitching thickness t = 0.06 × 4000^(1/3) = 0.95 m. Scour depth R = 0.47(4000/1.1)^(1/3) = 7.23 m; maximum scour at nose 2R = 14.45 m, shank 1.5R = 10.84 m. Apron width 1.5D': nose 14.2 m, shank 8.8 m; launched thickness 1.43 m.
Neatly sketch a guide bund and design the following components of a guide bund for a river discharge of 4000 m³/s, flood height 5.0 m and silt factor 1.1: (i) length of guide bund (ii) thickness of pitching (iii) width of launching apron (iv) depth of launching apron.
Data and design basis
- Silt factor given:
- Flood depth: m
- Design discharge for scour/apron: m³/s
1. Waterway and length of guide bund
Lacey's regime waterway: m. Adopt m. Length of guide bund (Garg): upstream shank to , downstream tail to . Adopt
Curved heads: upstream radius m with sweep to (adopt ); downstream radius m with sweep about . Arc length of upstream head m, so total length on the upstream side m.
2. Thickness of stone pitching
Adopt m (pitching on the river side slope 2:1, over a 0.15 to 0.3 m graded filter).
3. Scour depth and launching apron
Lacey's normal scour depth:
Maximum scour below HFL: at the upstream nose, at the shank (straight portion). The apron must launch to the slope , so its horizontal width is and, when launched, it covers a slope length with thickness .
| Portion | Scour factor | Scour depth below HFL | Depth below bed | Apron length |
|---|---|---|---|---|
| Nose (u/s curved head) | 2.0R | 14.45 m | 9.45 m | 14.18 m |
| Shank (straight) | 1.5R | 10.84 m | 5.84 m | 8.76 m |
Thickness: pitching m, so the launched apron thickness is m. Equating volumes per metre, the thickness as laid over width is m (about ).
Summary
| Item | Value |
|---|---|
| Lacey waterway | 300.42 m (adopt 300 m) |
| Length of guide bund (u/s) | 375 m; d/s tail 75 m |
| Pitching thickness | 0.95 m |
| Apron at shank: width / thickness | 8.76 m / 1.43 m launched (2.13 m laid) |
| Apron at nose: width / thickness | 14.18 m / 1.43 m launched (2.13 m laid) |
Sketches
Plan of guide bunds:
U/S D/S
bridge / weir axis
Shank (straight) |
________________________________ | ___
/ 1.0-1.5 W upstream \ | / \ tail
\________________________________/=|=\___/ 0.25 W
curved head |
R, sweep 120 deg <-- waterway W -->
________________________________ | ___
/ \ | / \
\________________________________/=|=\___/
Section at the shank (straight portion):
top width 6 m
___________ <- HFL + 1.5 m
/ \
HFL ---/-------------\--- 2:1 slopes
/ pitching t \
bed__/__ filter ______ \___
\_ launching apron _/ (launches at 2:1)
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Guide bund design, 4000 m3/s, d 0.1 mm · Irrigation and Drainage Engineering, chapter 6
- Guide bund components and drawings, 6000 m3/s · Irrigation and Drainage Engineering, chapter 6
- Guide bund: length, curved head, apron; 4500 m3/s · Irrigation and Drainage Engineering, chapter 6 · asked 2×
- Gabion guide bund and apron, 3000 m3/s · Irrigation and Drainage Engineering, chapter 6 · asked 2×
- Guide bank and launching apron, 5000 m3/s · Irrigation and Drainage Engineering, chapter 6
- Guide bund and apron, 13,100 m3/s · Irrigation and Drainage Engineering, chapter 6
All Irrigation and Drainage Engineering chapter 6 questions →