- 2079 Bhadra · 14 marks
Footing for 30x35 cm column, M25
Short answer
Provide a 3.2 m × 1.9 m footing, 650 mm thick. Reinforcement: along length, 12 mm bars @ 140 mm c/c; along width, central band with 17 bars of 12 mm @ 110 mm c/c and each outer strip with 5 bars of 12 mm @ 130 mm c/c.
Design a footing for a rectangular column of size 30 cm x 35 cm reinforced with 8-20 mm dia. bars. The column is subjected to a factored axial load and moment of 1000 kN and 80 kN-m, respectively. The allowable bearing capacity of soil is 140 kN/m. At a depth of 1.6 m. Use M25 concrete and TMT bars for column and footing both. Sketch all of the reinforcement required.
Data and assumptions
- Column 350 mm × 300 mm (long side mm along the footing length); footing concrete M25, steel Fe500; column concrete M25; column bars 8-20 mm.
- Given loads are factored: kN, kN·m. Service loads = factored / 1.5: kN, kN·m.
- Allowable (safe) bearing capacity of soil = 140 kN/m² at 1.6 m depth.
- TMT bars taken as Fe500.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth mm (cover + half bar). Load factor 1.5.
Size of footing
Weight of footing and backfill is taken as 10% of the column load.
Eccentricity m, which is less than , so there is no tension under the base. The size is chosen so that
Try m ( m²): kN/m² and kN/m² . Safe.
Factored soil pressure
kN, kN·m. : kN/m², kN/m² (average 164.5 kN/m²). Self-weight does not cause bending in the footing, so it is excluded.
Bending moments and reinforcement
Cantilever projections from the column face: along : mm; along : mm. Along (critical section at the column face on the side of maximum pressure, linear pressure): , with kN/m² at the face and m: kN·m. Along (average pressure): kN·m. Required depth for flexure: is far larger than the moment for mm, so the depth is governed by shear (one-way or punching). Trial mm, mm, found by the shear checks below.
; minimum steel = 0.12% of .
| Direction | (kN·m) | req (mm²) | Provide | prov (mm²) |
|---|---|---|---|---|
| Along (width ) | 350.7 | 1482 (minimum) | 12 mm @ 140 c/c | 1535 |
| Along (width ) | 168.4 | 2496 | 12 mm @ 140 c/c | 2585 |
For the rectangular footing, the short-direction steel is placed in a central band of width mm in the proportion (IS 456 cl. 34.3.1), where .
- Central band: mm² → 12 mm @ 110 mm c/c (17 bars).
- Each outer strip (650 mm wide): remaining steel 318 mm² or minimum 0.12% = 507 mm², whichever is more → 12 mm @ 130 mm c/c (5 bars).
Check for one-way shear (at distance from the column face)
- Along side: kN, MPa; , MPa (IS 456 Table 19, SP 16 formula). , safe.
- Along side: kN, MPa; , MPa. Safe.
Check for two-way (punching) shear (at from the column face)
- Perimeter mm
- kN (average pressure; the effect of moment transfer is neglected).
- MPa; , MPa. , safe.
Development length
, MPa (M25, deformed bars): 12 mm bars (both directions) → mm. Available length from column face (less 50 mm end cover): 1375 mm along , 750 mm along . Satisfied in both directions.
Bearing stress and transfer of load from column
Column area m². Bearing stress MPa. Permissible bearing stress: column concrete MPa; footing concrete with gives up to 22.50 MPa. The lesser, 11.25 MPa, governs. Capacity of bearing = 1181 kN kN, so the whole load can be transferred by bearing. Provide minimum dowels of 0.5% of column area = 525 mm²: use 8 bars of 20 mm (2513 mm²) as dowels, same as column bars. Dowel length in compression mm (and the same lap with the column bars). Available depth in footing = 650 - 50 - 24 = 576 mm ; dowels are bent at the bottom with 90° bends.
Detailing
PLAN ELEVATION
+------------------+ col
| # # # # # # | | |
| # +------+ # # | _|_|__
| # | col | # # | |_____| <- D = 650 mm
| # +------+ # # | bars both ways
| # # # # # # |
+------------------+
L = 3.2 m, B = 1.9 m
- Bottom mesh: 12 mm @ 140 c/c along (lower layer); along (upper layer), 12 mm @ 110 c/c in the central 1.9 m band and 12 mm @ 130 c/c in each outer strip, 50 mm clear cover; dowels 8-20 mm.
Answer: Footing 3.2 m × 1.9 m × 650 mm thick; 12 mm @ 140 c/c along the length; along the width, 12 mm @ 110 c/c in the central 1.9 m band and 12 mm @ 130 c/c in the outer strips.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Footing 300x400 column, factored moment 120 kNm · Design of RCC Structure, chapter 11
- Footing 350x350, 8-16 mm bars, reversible moment · Design of RCC Structure, chapter 11
- Footing, 450x500 column, 6#20, uniaxial moment · Design of RCC Structure, chapter 11
- Rectangular footing, 450x450, uniaxial moment 240 kNm · Design of RCC Structure, chapter 11
- Footing with load transfer check, 1000 kN · Design of RCC Structure, chapter 11
- Rectangular column with working-load moment · Design of RCC Structure, chapter 10
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Circular footing 1 m dia, 1000 kN · Foundation Engineering, chapter 6
- Rectangular footing size, 6000 kN · Foundation Engineering, chapter 6
- Brick column 35 cm x 50 cm allowable load · Concrete Technology and Masonry Structure, chapter 8