- 2075 Chaitra · 10 marks
Isolated footing 350x350, 1500 kN
Short answer
Area = 1.1*1500/175 = 9.43 m², provide 3.1 m square. Factored pressure 234.1 kN/m²; depth D=650 mm (d=590 mm). Reinforcement 16 mm @ 185 c/c both ways; shear safe. Bearing stress 18.37 MPa > 9 MPa, excess 1148 kN requires dowels; column bars plus 4 extra 16 mm bars provide 3317 mm².
Design a R.C.C isolated footing to carry an axial load of 1500 kN. The column is 350 mm x 350 mm in size with 20 mm diameter, 8 Nos longitudinal bars. The bearing capacity of soil is 175 kN/m. Use M20 grade concrete and Fe415 grade steel. Assume missing datas.
Data and assumptions
- Column 350 mm × 350 mm (long side mm along the footing length); footing concrete M20, steel Fe415; column concrete M20; column bars 8-20 mm.
- Service load kN.
- Allowable (safe) bearing capacity of soil = 175 kN/m².
- Axial load taken as service load; column concrete M20 assumed.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth mm (cover + half bar). Load factor 1.5.
Size of footing
Weight of footing and backfill is taken as 10% of the column load.
Provide a square footing m, area = 9.61 m² 9.43 m².
Factored soil pressure
kN. kN/m².
Bending moments and reinforcement
Cantilever projections from the column face: along : mm; along : mm. : kN·m, kN·m. Required depth for flexure: is far larger than the moment for mm, so the depth is governed by shear (one-way or punching). Trial mm, mm, found by the shear checks below.
; minimum steel = 0.12% of .
| Direction | (kN·m) | req (mm²) | Provide | prov (mm²) |
|---|---|---|---|---|
| Along (width ) | 686.1 | 3350 | 16 mm @ 185 c/c | 3369 |
| Along (width ) | 686.1 | 3350 | 16 mm @ 185 c/c | 3369 |
Check for one-way shear (at distance from the column face)
- Along side: kN, MPa; , MPa (IS 456 Table 19, SP 16 formula). , safe.
- Along side: kN, MPa; , MPa. Safe.
Check for two-way (punching) shear (at from the column face)
- Perimeter mm
- kN (average pressure; the effect of moment transfer is neglected).
- MPa; , MPa. , safe.
Development length
, MPa (M20, deformed bars): 16 mm bars (both directions) → mm. Available length from column face (less 50 mm end cover): 1325 mm along , 1325 mm along . Satisfied in both directions.
Bearing stress and transfer of load from column
Column area m². Bearing stress MPa. Permissible bearing stress: column concrete MPa; footing concrete with gives up to 18.00 MPa. The lesser, 9.00 MPa, governs. Capacity of bearing = 1102 kN kN, so the excess 1148 kN must be carried by dowels: mm²; the column bars (8-20 mm, 2513 mm²) are continued into the footing as dowels, and 4 extra bars of 16 mm (804 mm²) are added, giving 3317 mm² 3178 mm². Dowel length in compression mm (and the same lap with the column bars). Available depth in footing = 650 - 50 - 32 = 568 mm ; dowels are bent at the bottom with 90° bends.
Detailing
PLAN ELEVATION
+------------------+ col
| # # # # # # | | |
| # +------+ # # | _|_|__
| # | col | # # | |_____| <- D = 650 mm
| # +------+ # # | bars both ways
| # # # # # # |
+------------------+
L = 3.1 m, B = 3.1 m
- Bottom mesh: 16 mm @ 185 c/c along (lower layer), 16 mm @ 185 c/c along (upper layer), 50 mm clear cover; dowels 8-20 mm.
Answer: Footing 3.1 m × 3.1 m × 650 mm thick; 16 mm @ 185 c/c along the length and 16 mm @ 185 c/c along the width.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Footing 350x350, 8-16 mm bars, reversible moment · Design of RCC Structure, chapter 11
- Footing, 1250 kN column load, depth 1.8 m · Design of RCC Structure, chapter 11
- Footing for 400x400 column, 1500 kN · Design of RCC Structure, chapter 11
- Isolated footing 450x450, service moment 110 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Footing, 450x500 column, 6#20, uniaxial moment · Design of RCC Structure, chapter 11
- Isolated footing 400x400, service moment 120 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Box deodar column, 60 mm planks, 350 kN · Design of Steel and Timber Structure, chapter 11
- Footing size from plate load test curve · Foundation Engineering, chapter 6
- Built-up column, two channels toe-to-toe, 1500 kN · Design of Steel and Timber Structure, chapter 6