Isolated footing 500x500 with moment, M25
Short answer
Square footing 3.1 m × 3.1 m, overall depth 650 mm (effective 590 mm). Main reinforcement 16 mm @ 185 mm c/c both ways; one-way and punching shear are within limits.
Design an isolated footing to carry a column load of 1300 kN and BM of 100 kN-m from both axes of column. Column is 500 mm x 500 mm in size with 25 mm diameter longitudinal steel. The bearing capacity of soil is 220 kN/m. Consider depth of foundation as 1.70 m. Take unit weight of soil as 18.5 kN/m. Use M25 grade concrete and Fe415 steel.
Data and assumptions
- Column 500 mm × 500 mm (long side mm along the footing length); footing concrete M25, steel Fe415; column concrete M25; column bars 8-25 mm.
- Service load kN, service moment kN·m (about the other axis also 100 kN·m).
- Allowable (safe) bearing capacity of soil = 220 kN/m² at 1.7 m depth, soil unit weight 18.5 kN/m³.
- Loads are service loads; moments of 100 kN·m act about both axes, so a square footing is used.
- Clear cover 50 mm for the footing (IS 456 cl. 26.4.2.2); effective depth mm (cover + half bar). Load factor 1.5.
Size of footing
Net safe bearing capacity = kN/m² (this takes care of the weight of footing and backfill).
Eccentricity m (and 0.077 m in the other direction), which is less than , so there is no tension under the base. The size is chosen so that
Try m ( m²): kN/m² and kN/m² . Safe.
Factored soil pressure
kN, kN·m. : kN/m², kN/m² (average 202.9 kN/m²). Self-weight does not cause bending in the footing, so it is excluded.
Bending moments and reinforcement
Cantilever projections from the column face: along : mm; along : mm. With the maximum pressure assumed over the cantilever (conservative): kN·m, kN·m. Required depth for flexure: is far larger than the moment for mm, so the depth is governed by shear (one-way or punching). Trial mm, mm, found by the shear checks below.
; minimum steel = 0.12% of .
| Direction | (kN·m) | req (mm²) | Provide | prov (mm²) |
|---|---|---|---|---|
| Along (width ) | 689.8 | 3341 | 16 mm @ 185 c/c | 3369 |
| Along (width ) | 689.8 | 3341 | 16 mm @ 185 c/c | 3369 |
Check for one-way shear (at distance from the column face)
- Along side: kN, MPa; , MPa (IS 456 Table 19, SP 16 formula). , safe.
- Along side: kN, MPa; , MPa. Safe.
Check for two-way (punching) shear (at from the column face)
- Perimeter mm
- kN (average pressure; the effect of moment transfer is neglected).
- MPa; , MPa. , safe.
Development length
, MPa (M25, deformed bars): 16 mm bars (both directions) → mm. Available length from column face (less 50 mm end cover): 1250 mm along , 1250 mm along . Satisfied in both directions.
Bearing stress and transfer of load from column
Column area m². Bearing stress MPa. Permissible bearing stress: column concrete MPa; footing concrete with gives up to 22.50 MPa. The lesser, 11.25 MPa, governs. Capacity of bearing = 2812 kN kN, so the whole load can be transferred by bearing. Provide minimum dowels of 0.5% of column area = 1250 mm²: use 8 bars of 25 mm (3927 mm²) as dowels, same as column bars. Dowel length in compression mm (and the same lap with the column bars). Available depth in footing = 650 - 50 - 32 = 568 mm ; dowels are bent at the bottom with 90° bends.
Detailing
PLAN ELEVATION
+------------------+ col
| # # # # # # | | |
| # +------+ # # | _|_|__
| # | col | # # | |_____| <- D = 650 mm
| # +------+ # # | bars both ways
| # # # # # # |
+------------------+
L = 3.1 m, B = 3.1 m
- Bottom mesh: 16 mm @ 185 c/c along (lower layer), 16 mm @ 185 c/c along (upper layer), 50 mm clear cover; dowels 8-25 mm.
Answer: Footing 3.1 m × 3.1 m × 650 mm thick; 16 mm @ 185 c/c along the length and 16 mm @ 185 c/c along the width.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Isolated footing 500x500, 1600 kN · Design of RCC Structure, chapter 11
- Isolated footing 400x400, service moment 120 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Isolated footing 450x450, service moment 110 kNm · Design of RCC Structure, chapter 11 · asked 2×
- Isolated footing 350x350, 1500 kN · Design of RCC Structure, chapter 11
- Footing for 30x35 cm column, M25 · Design of RCC Structure, chapter 11
- Footing, 1250 kN column load, depth 1.8 m · Design of RCC Structure, chapter 11
- Greatest bolt force, 100 kN at 500 mm · Design of Steel and Timber Structure, chapter 4
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Footing size from plate load test curve · Foundation Engineering, chapter 6
- Fillet weld size for bracket plate, 100 kN · Design of Steel and Timber Structure, chapter 4