For undamped upsurge, Z_max = ΔV √(L A_t / g A_s). For the given plant, with ΔV = 1.732 m/s, permissible surge 10 m, the minimum surge tank area is approximately 1800 m², and the corresponding headrace tunnel length is about 15.3 km.

Derive an expression for minimum upsurge without damping effect in the surge chamber using continuity and momentum equations [3]. In a storage hydropower plant, water is delivered from the upper impounding reservoir through a low pressure headrace tunnel and three high pressure penstocks to three Francis turbine units. The elevations of the reservoir and tailwater level are 320 m and 200 m above datum respectively. It is decided to design a simple surge tank between the headrace tunnel and penstocks for sudden rejection or demand of two units. If the maximum and minimum water level elevation in the surge tank is limited to 330 m and 310 m above datum respectively due to topography and construction difficulty, determine the minimum area of the surge tank and the permissible length of the low pressure headrace tunnel to fulfil the design objective. Given: discharge in tunnel = 100 m³/s; headrace tunnel diameter = 7 m and head loss in tunnel = 10% of gross head of the system; penstocks: each length 500 m, diameter 2.5 m, f = 0.016.

Part 1: Derivation (no friction)

Let zz be the water level in the tank above the reservoir level (positive upward), VV the velocity in the tunnel (length LL, area AtA_t), AsA_s the area of the tank, and QtQ_t the turbine flow after the sudden change.

 reservoir ~~~~~~~~
            \___________ tunnel L, A_t, V ___________ surge tank
                                              | z    |  A_s
                                              |______|__ to turbine Q_t

Continuity at the tank junction: inflow from the tunnel = flow to the tank + flow to the turbine

AtV=Asdzdt+Qt(1)A_tV=A_s\frac{dz}{dt}+Q_t \quad (1)

Momentum for the water column in the tunnel (net force = mass x acceleration; the head zz acts to decelerate the flow):

ρAtLdVdt=−ρgAtz ⇒ LgdVdt=−z(2)\rho A_tL\frac{dV}{dt}=-\rho gA_t z\ \Rightarrow\ \frac{L}{g}\frac{dV}{dt}=-z \quad (2)

Differentiate (1) with QtQ_t constant: AtdVdt=Asd2zdt2A_t\dfrac{dV}{dt}=A_s\dfrac{d^2z}{dt^2}. Substituting in (2):

d2zdt2+gAtLAs z=0\frac{d^2z}{dt^2}+\frac{gA_t}{LA_s}\,z=0

This is simple harmonic motion with ω=gAtLAs\omega=\sqrt{\dfrac{gA_t}{LA_s}}, so the period is T=2πLAsgAtT=2\pi\sqrt{\dfrac{LA_s}{gA_t}}.

Boundary conditions at t=0t=0 (sudden change of discharge from Q0Q_0 to QtQ_t, so ΔV=Q0−QtAt\Delta V=\dfrac{Q_0-Q_t}{A_t}): z=0z=0 and dzdt=AtΔVAs\dfrac{dz}{dt}=\dfrac{A_t\Delta V}{A_s}. Hence

z=AtΔVAs ωsin⁡ωt,Zmax=AtΔVAsLAsgAtz=\frac{A_t\Delta V}{A_s\,\omega}\sin\omega t,\qquad Z_{max}=\frac{A_t\Delta V}{A_s}\sqrt{\frac{LA_s}{gA_t}} Zmax=ΔVL Atg As\boxed{Z_{max}=\Delta V\sqrt{\frac{L\,A_t}{g\,A_s}}}

For load rejection this is the upsurge +Zmax+Z_{max}; for sudden demand the same magnitude is the downsurge −Zmax-Z_{max} (undamped).

Part 2: Numerical design

Given: reservoir RL 320 m, tailwater RL 200 m, gross head H0=120H_0=120 m; Q=100Q=100 m³/s for three units, so each unit takes 33.333.3 m³/s; two units are rejected or demanded, so the change is ΔQ=66.7\Delta Q=66.7 m³/s. Maximum and minimum tank levels are RL 330 m and RL 310 m, so Z=330−320=10Z=330-320=10 m upwards and 320−310=10320-310=10 m downwards. Tunnel D=7D=7 m, tunnel head loss hf=10%H0=12h_f=10\%H_0=12 m. Penstocks: 3 x 500 m, D=2.5D=2.5 m, f=0.016f=0.016. The friction factor of the tunnel is assumed to be the same as the penstocks, f=0.016f=0.016.

Tunnel velocity and change in velocity

At=π4(7)2=38.48 m2,V0=10038.48=2.598 m/s,ΔV=23V0=1.732 m/sA_t=\frac{\pi}{4}(7)^2=38.48\ \text{m}^2,\quad V_0=\frac{100}{38.48}=2.598\ \text{m/s},\quad \Delta V=\frac{2}{3}V_0=1.732\ \text{m/s}

Length of the tunnel (from the head loss, Darcy-Weisbach)

hf=f LDV022g ⇒ L=2gD hffV02=19.62×7×120.016×6.752=15256 m (≈15.3 km)h_f=\frac{f\,L}{D}\frac{V_0^2}{2g}\ \Rightarrow\ L=\frac{2gD\,h_f}{fV_0^2}=\frac{19.62\times7\times12}{0.016\times6.752}=15256\ \text{m}\ (\approx15.3\ \text{km})

Area of the tank from the permissible surge (Z=10Z=10 m both ways)

Z2=ΔV2L Atg As ⇒ As=ΔV2 L Atg Z2=3.001×15256×38.489.81×100=1796 m2Z^2=\Delta V^2\frac{L\,A_t}{g\,A_s}\ \Rightarrow\ A_s=\frac{\Delta V^2\,L\,A_t}{g\,Z^2}=\frac{3.001\times15256\times38.48}{9.81\times100}=1796\ \text{m}^2

This corresponds to a circular tank of diameter 4As/π=47.8\sqrt{4A_s/\pi}=47.8 m.

Thoma check (stability)

α=hfV02=126.752=1.777 s2/m\alpha=\frac{h_f}{V_0^2}=\frac{12}{6.752}=1.777\ \text{s}^2/\text{m}

Penstock velocity Vp=33.3π4(2.5)2=6.79V_p=\dfrac{33.3}{\frac{\pi}{4}(2.5)^2}=6.79 m/s and its loss hp=0.016×5002.56.79219.62=7.52h_p=\dfrac{0.016\times500}{2.5}\dfrac{6.79^2}{19.62}=7.52 m. Net head H0−hf−hp=120−12−7.52=100.5H_0-h_f-h_p=120-12-7.52=100.5 m.

Ath=L At2g α (H0−hf−hp)=15256×38.4819.62×1.777×100.5=168 m2A_{th}=\frac{L\,A_t}{2g\,\alpha\,(H_0-h_f-h_p)}=\frac{15256\times38.48}{19.62\times1.777\times100.5}=168\ \text{m}^2

Since As=1796A_s=1796 m² >Ath=168>A_{th}=168 m², the tank is stable.

Period of oscillation: T=2πLAsgAt=1693T=2\pi\sqrt{\dfrac{LA_s}{gA_t}}=1693 s (about 28.2 min).

Answer: minimum area of the surge tank As≈1800A_s\approx1800 m² (diameter about 48 m) and the permissible tunnel length L≈15250L\approx15250 m (about 15.3 km), with the surge limited to RL 330 m and RL 310 m.

✓ Answer checked by Claude Opus 5.5 (high effort)