Design: 25 kVA 11000/433 V distribution transformer

Short answer

Core: d=134.5 mm, limb 114.4×71.3 mm; window 114.9×287.3 mm; yoke depth 114.4 mm, height 118.2 mm. Overall frame 523.6×613.2×114.4 mm. Per-unit resistance, reactance, regulation, and efficiency are not fully computed in the provided solution.

Design a 25 kVA, 11000/433 V, 50 Hz, 3 phase, delta/star core type distribution transformer. The required data for design are given below: Maximum flux density in core = 1 Wb/m²; Current density in conductor = 2.3 A/mm²; Constant for output volt per turn, K = 0.45; Core type = cruciform; Window space factor, Kw = 8/(30+kV); Stacking factor = 0.9; Ratio of window height to width = 2.5; Take area of yoke 20% more than area of limb; Width of LV winding = 9.1 mm; Width of HV winding = 26.22 mm; Total losses at full load = 901 W. Calculate: i) Dimensions of core, window and yoke ii) Overall dimensions of the frame iii) Per unit resistance and leakage reactance drop iv) Per unit voltage regulation at 0.8 pf v) Full load efficiency at 0.8 pf

Standard method (A.K. Sawhney, A Course in Electrical Machine Design): Et=KQE_t = K\sqrt{Q}, net core area ratio for the core type, output equation for the window, yoke depth = width of largest stamping. Assumed: clearance core-to-LV 2 mm, LV-to-HV duct 15 mm, end clearance 20 mm, ρ=0.021 Ω\rho = 0.021\ \Omega-mm²/m.

i) Dimensions of core, window and yoke

Voltage per turn, Et=KQE_t = K\sqrt{Q} (QQ in kVA, total for 3 phases):

Et=0.4525=2.250 Vϕm=Et4.44f=2.2504.44×50=0.01014 WbAi=ϕmBm=0.010141=0.01014 m2=101.4 cm2\begin{aligned} E_t &= 0.45\sqrt{25} = 2.250\ \text{V}\\ \phi_m &= \frac{E_t}{4.44f} = \frac{2.250}{4.44\times50} = 0.01014\ \text{Wb}\\ A_i &= \frac{\phi_m}{B_m} = \frac{0.01014}{1} = 0.01014\ \text{m}^2 = 101.4\ \text{cm}^2 \end{aligned}

For a cruciform (two-stepped) core with stacking factor 0.9, Ai=0.56d2A_i = 0.56d^2 (standard ratio, Sawhney):

d=Ai0.56=0.010140.56=0.1345 m=134.5 mma=0.85d=114.4 mmb=0.53d=71.3 mm\begin{aligned} d &= \sqrt{\frac{A_i}{0.56}} = \sqrt{\frac{0.01014}{0.56}} = 0.1345\ \text{m} = 134.5\ \text{mm}\\ a &= 0.85d = 114.4\ \text{mm}\\ b &= 0.53d = 71.3\ \text{mm} \end{aligned}

Gross core area Agi=Ai/0.9=0.01126A_{gi} = A_i/0.9 = 0.01126 m².

Output equation (three phase): Q=3.33fBmδKwAwAi×10−3Q = 3.33fB_m\delta K_wA_wA_i\times10^{-3}

Window space factor Kw=830+kV=830+11=0.1951K_w = \dfrac{8}{30 + kV} = \dfrac{8}{30 + 11} = 0.1951

Aw=Q3.33fBmδKwAi×10−3=253.33×50×1×2.3×106×0.195×0.01014×10−3=0.03301 m2Ww=Aw2.5=114.9 mm,Hw=2.5Ww=287.3 mmD=d+Ww=249.4 mm (distance between adjacent limb centres)\begin{aligned} A_w &= \frac{Q}{3.33fB_m\delta K_wA_i\times10^{-3}}\\ &= \frac{25}{3.33\times50\times1\times2.3\times10^6\times0.195\times0.01014\times10^{-3}}\\ &= 0.03301\ \text{m}^2\\ W_w &= \sqrt{\frac{A_w}{2.5}} = 114.9\ \text{mm},\quad H_w = 2.5W_w = 287.3\ \text{mm}\\ D &= d + W_w = 249.4\ \text{mm (distance between adjacent limb centres)} \end{aligned}

Yoke:

Yoke area 20% more than core area (hot-rolled steel, to reduce yoke loss and magnetising current). Yoke depth = width of largest stamping:

Ay=1.2Ai=0.01216 m2,Agy=Ay0.9=0.01351 m2Dy=a=114.4 mmHy=AgyDy=0.013510.1144=118.2 mm\begin{aligned} A_y &= 1.2A_i = 0.01216\ \text{m}^2,\quad A_{gy} = \frac{A_y}{0.9} = 0.01351\ \text{m}^2\\ D_y &= a = 114.4\ \text{mm}\\ H_y &= \frac{A_{gy}}{D_y} = \frac{0.01351}{0.1144} = 118.2\ \text{mm} \end{aligned}

ii) Overall dimensions of frame

H=Hw+2Hy=287.3+2(118.2)=523.6 mmW=2D+a=2(249.4)+114.4=613.2 mmDepth=Dy=a=114.4 mm\begin{aligned} H &= H_w + 2H_y = 287.3 + 2(118.2) = 523.6\ \text{mm}\\ W &= 2D + a = 2(249.4) + 114.4 = 613.2\ \text{mm}\\ \text{Depth} &= D_y = a = 114.4\ \text{mm} \end{aligned}
 +-----------------------------+  ---
 |          top yoke           |   ^
 +-----+-----+-----+-----+-----+   |
 |limb |     |limb |     |limb |   |
 |  R  | Ww  |  Y  | Ww  |  B  |   H
 |     |     |     |     |     |   |
 +-----+-----+-----+-----+-----+   |
 |         bottom yoke         |   v
 +-----------------------------+  ---
 |<------------ W ------------>|
    |<--- D --->|<--- D --->|

iii) Per unit resistance and leakage reactance drop

Phase voltages: LV (star) VLV=250.0V_{LV} = 250.0 V; HV (delta) VHV=11000.0V_{HV} = 11000.0 V.

Phase currents: ILV=Q3VLV=33.33I_{LV} = \frac{Q}{3V_{LV}} = 33.33 A; IHV=0.758I_{HV} = 0.758 A.

TLV=VLVEt=250.02.250=111.11≈111Et (revised)=250.0111=2.252 VTHV=TLVVHVVLV=4884.1≈4884aLV=ILVδ=14.49 mm2,aHV=IHVδHV=0.329 mm2\begin{aligned} T_{LV} &= \frac{V_{LV}}{E_t} = \frac{250.0}{2.250} = 111.11 \approx 111\\ E_t\ (\text{revised}) &= \frac{250.0}{111} = 2.252\ \text{V}\\ T_{HV} &= T_{LV}\frac{V_{HV}}{V_{LV}} = 4884.1 \approx 4884\\ a_{LV} &= \frac{I_{LV}}{\delta} = 14.49\ \text{mm}^2,\quad a_{HV} = \frac{I_{HV}}{\delta_{HV}} = 0.329\ \text{mm}^2 \end{aligned}

Radial build (assumed clearance between core and LV = 2 mm):

ItemInside dia (mm)Outside dia (mm)
LV winding138.5156.7
HV winding186.7239.2

Radial depths: b1=9.1b_1 = 9.1 mm (LV), b2=26.22b_2 = 26.22 mm (HV), duct a=15a = 15 mm. Axial length Lc=Hw−2(20)=247.3L_c = H_w - 2(20) = 247.3 mm.

Mean lengths of turn:

Lmt,LV=π138.5+156.72=0.4638 mLmt,HV=π186.7+239.22=0.6690 mLmt=π138.5+239.22=0.5933 m (both windings, for reactance)\begin{aligned} L_{mt,LV} &= \pi\frac{138.5 + 156.7}{2} = 0.4638\ \text{m}\\ L_{mt,HV} &= \pi\frac{186.7 + 239.2}{2} = 0.6690\ \text{m}\\ L_{mt} &= \pi\frac{138.5 + 239.2}{2} = 0.5933\ \text{m (both windings, for reactance)} \end{aligned}

Check: HV outside diameter 239 mm vs DD = 249 mm. Adjacent HV coils have about 10 mm clearance, so the coils fit.

Resistance referred to HV, with ρ=0.021 Ω-mm2/m\rho = 0.021\ \Omega\text{-mm}^2/\text{m} (copper at about 75 °C):

rHV=ρTHVLmt,HVaHV=0.021×4884×0.66900.329=208.32 ΩrLV=0.021×111×0.463814.49=0.074594 ΩRp=rHV+rLV(THVTLV)2=208.32+0.074594(4884111)2=352.73 Ωεr=IHVRpVHV=0.7576×352.7311000.0=0.02429 p.u.\begin{aligned} r_{HV} &= \frac{\rho T_{HV}L_{mt,HV}}{a_{HV}} = \frac{0.021\times4884\times0.6690}{0.329} = 208.32\ \Omega\\ r_{LV} &= \frac{0.021\times111\times0.4638}{14.49} = 0.074594\ \Omega\\ R_p &= r_{HV} + r_{LV}\left(\frac{T_{HV}}{T_{LV}}\right)^2 = 208.32 + 0.074594\left(\frac{4884}{111}\right)^2 = 352.73\ \Omega\\ \varepsilon_r &= \frac{I_{HV}R_p}{V_{HV}} = \frac{0.7576\times352.73}{11000.0} = 0.02429\ \text{p.u.} \end{aligned}

Leakage reactance (per unit), with ATAT per limb =3700= 3700 and axial winding length Lc=247.3L_c = 247.3 mm:

εx=2πfμ0ATLc⋅LmtEt(a+b1+b23)=2π(50)(4π×10−7)37000.2473⋅0.59332.252(15+9.1+26.223)×10−3=0.0417 p.u.\begin{aligned} \varepsilon_x &= 2\pi f\mu_0\frac{AT}{L_c}\cdot\frac{L_{mt}}{E_t}\left(a + \frac{b_1+b_2}{3}\right)\\ &= 2\pi(50)(4\pi\times10^{-7})\frac{3700}{0.2473}\cdot\frac{0.5933}{2.252}\left(15 + \frac{9.1+26.22}{3}\right)\times10^{-3}\\ &= 0.0417\ \text{p.u.} \end{aligned}

iv) Per unit regulation at 0.8 pf lagging

ε=εrcos⁡ϕ+εxsin⁡ϕ=0.02429(0.8)+0.0417(0.600)=0.0444 p.u.=4.44%\begin{aligned} \varepsilon &= \varepsilon_r\cos\phi + \varepsilon_x\sin\phi\\ &= 0.02429(0.8) + 0.0417(0.600) = 0.0444\ \text{p.u.} = 4.44\% \end{aligned}

v) Full-load efficiency at 0.8 pf

Output =25×0.8=20= 25\times0.8 = 20 kW; total full-load loss = 901 W.

η=2020+0.901×100=95.69%\eta = \frac{20}{20 + 0.901}\times100 = 95.69\%

(Copper loss from the resistance above: 3IHV2Rp3I_{HV}^2R_p = 607 W, so the iron loss is about 294 W.)

Answer: dd = 134.5 mm, window 115 × 287 mm; frame 524 × 613 × 114 mm; εr\varepsilon_r = 0.0243, εx\varepsilon_x = 0.0417; regulation ≈ 4.44%; efficiency ≈ 95.69%.