Design: 100 kVA 4000/433 V distribution transformer
Short answer
Cruciform core d=167 mm, stampings 142×88 mm; window 344 mm high × 138 mm wide; yoke depth 142 mm, height 147 mm; overall frame 637×751×142 mm. Per unit voltage regulation at 0.8 pf lagging is 0.0423 (4.23%).
The design parameters for a 100 kVA, 4000/433 V, 50 Hz, 3-phase, Δ/Y core type oil immersed natural cooled distribution transformer are given below. Max. flux density in core = 1.3 Wb/m²; Current density in conductor = 2.5 A/mm²; Constant for output voltage per turn = 0.45; Core type = cruciform; Window space factor = 0.25; Stacking factor = 0.9; Ratio of window height to width = 2.5; Width of LV winding = 20 mm; Width of HV winding = 25 mm; Width of duct between HV and LV = 15 mm. Take hot rolled steel and area of yoke is 20% greater than area of core. Calculate: (i) Dimension of the core, window and yoke (ii) Overall dimension of the frame (iii) Per unit voltage regulation at 0.8 pf
Standard method (A.K. Sawhney, A Course in Electrical Machine Design): , net core area ratio for the core type, output equation for the window, yoke depth = width of largest stamping. Assumed: core-to-LV clearance 5 mm, end clearance 20 mm, -mm²/m.
(i) Dimensions of core, window and yoke
Voltage per turn, ( in kVA, total for 3 phases):
For a cruciform (two-stepped) core with stacking factor 0.9, (standard ratio, Sawhney):
Gross core area m².
Output equation (three phase):
Yoke:
Yoke area 20% more than core area (hot-rolled steel, to reduce yoke loss and magnetising current). Yoke depth = width of largest stamping:
(ii) Overall dimensions of frame
+-----------------------------+ ---
| top yoke | ^
+-----+-----+-----+-----+-----+ |
|limb | |limb | |limb | |
| R | Ww | Y | Ww | B | H
| | | | | | |
+-----+-----+-----+-----+-----+ |
| bottom yoke | v
+-----------------------------+ ---
|<------------ W ------------>|
|<--- D --->|<--- D --->|
(iii) Per unit voltage regulation at 0.8 pf lagging
Turns and conductors
Phase voltages: LV (star) V; HV (delta) V.
Phase currents: A; A.
Winding build
Radial build (assumed clearance between core and LV = 5 mm):
| Item | Inside dia (mm) | Outside dia (mm) |
|---|---|---|
| LV winding | 176.9 | 216.9 |
| HV winding | 246.9 | 296.9 |
Radial depths: mm (LV), mm (HV), duct mm. Axial length mm.
Mean lengths of turn:
Check: HV outside diameter 296.9 mm < = 304.6 mm (about 8 mm between adjacent coils; just adequate at 4 kV).
Resistance
Resistance referred to HV, with (copper at about 75 °C):
Reactance
Leakage reactance (per unit), with per limb and axial winding length mm:
Regulation
Answer: = 167 mm, window 138 × 344 mm, yoke 147 × 142 mm; frame 637 × 751 × 142 mm; regulation ≈ 4.29%.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Design: 150 kVA 6600/400 V distribution transformer · Electric Machine Design, chapter 3 · asked 5×
- Design: 4000 kVA 66/11 kV power transformer · Electric Machine Design, chapter 3 · asked 5×
- Design: 100 kVA 2200/480 V single phase transformer · Electric Machine Design, chapter 3 · asked 3×
- Design: 25 kVA 11000/433 V distribution transformer · Electric Machine Design, chapter 3
- Design: 100 kVA 11/132 kV transformer with winding data · Electric Machine Design, chapter 3 · asked 3×
- Design: 150 kVA 11000/420 V distribution transformer · Electric Machine Design, chapter 3 · asked 3×
- Design: 500 kVA single phase transformer with tubes · Electric Machine Design, chapter 3 · asked 2×
- Design: 125 kVA 6600/400 V three phase transformer · Electric Machine Design, chapter 3 · asked 4×
- Air gap flux density in core with three windings · Electrical Machines I, chapter 1
- Primary current and efficiency of 100 kVA Δ/Y transformer · Electrical Machines I, chapter 2
- Flux density in circular iron core · Electrical Machines, chapter 1
- 3-phase 500 kVA transformer primary current · Electrical Machines, chapter 2