Output (kVA) equation of single phase transformer

Short answer

The kVA rating is Q = 2.22 f Bₘ δ K_w A_w Aᵢ × 10⁻³. It comes from the EMF per turn 4.44fBₘAᵢ, the copper area K_wA_w = 2(AT)/δ, and the relation AT = V/(4.44fBₘAᵢ), yielding the product of core and window areas.

Derive an expression for kVA output of a single phase transformer from design point of view.

The output equation relates the kVA rating of a transformer to its main dimensions (net core area AiA_i and window area AwA_w) through the chosen magnetic loading BmB_m and electric loading δ\delta. It is the starting point of transformer design.

Notation

  • ff = frequency (Hz), BmB_m = maximum flux density (Wb/m²), ϕm=BmAi\phi_m = B_mA_i
  • AiA_i = net iron area of limb (m²), AwA_w = window area (m²)
  • KwK_w = window space factor = copper area / window area
  • δ\delta = current density (A/m²), TT = turns, II = current
  • Subscripts 1, 2 for primary and secondary

Step 1: Voltage

EMF per turn and terminal voltage (neglecting drops):

Et=4.44fϕm=4.44fBmAi,V≈E=4.44fBmAiTE_t = 4.44 f\phi_m = 4.44fB_mA_i, \qquad V \approx E = 4.44fB_mA_iT

Step 2: Window (copper) area

In a single-phase core type transformer the window holds one primary and one secondary winding (half of each on each limb, but a full set passes through the window).

a1=I1δ,a2=I2δCopper area in window=T1a1+T2a2=T1I1+T2I2δ=2ATδ\begin{aligned} a_1 &= \frac{I_1}{\delta},\quad a_2 = \frac{I_2}{\delta}\\ \text{Copper area in window} &= T_1a_1 + T_2a_2 = \frac{T_1I_1 + T_2I_2}{\delta} = \frac{2AT}{\delta} \end{aligned}

since T1I1=T2I2=ATT_1I_1 = T_2I_2 = AT. This copper area is also KwAwK_wA_w, so

KwAw=2ATδ  ⇒  AT=KwAwδ2K_wA_w = \frac{2AT}{\delta} \;\Rightarrow\; AT = \frac{K_wA_w\delta}{2}

Step 3: Output

Q=V1I1×10−3=4.44fBmAiT1I1×10−3=4.44fBmAi⋅KwAwδ2×10−3Q=2.22 f Bm δ Kw Aw Ai×10−3 kVA\begin{aligned} Q &= V_1I_1\times10^{-3} = 4.44fB_mA_iT_1I_1\times10^{-3}\\ &= 4.44fB_mA_i \cdot \frac{K_wA_w\delta}{2}\times10^{-3}\\ Q &= 2.22\,f\,B_m\,\delta\,K_w\,A_w\,A_i\times10^{-3}\ \text{kVA} \end{aligned}

Remarks

  • The same equation applies to a single-phase shell type transformer, because there too the window carries one full set of windings.
  • For a given rating, higher BmB_m or δ\delta gives a smaller core and window, but increases iron or copper losses and temperature rise.
  • In design, Et=KQE_t = K\sqrt{Q} is used first to get AiA_i; the output equation then gives AwA_w.