- 2076 Asoj · 8 marks
Emf and regulation of 1500 kVA 13 kV alternator
Short answer
Rated Vph=7505.6 V, I=66.62 A. Unity pf: E=√((V+IRa)²+(IXs)²) = 7584.3 V/phase, regulation 1.05%. 0.8 pf lagging: E=√((Vcosφ+IRa)²+(Vsinφ+IXs)²) = 7883.0 V/phase, regulation 5.03%.
A three phase, star connected 1500 kVA, 13 kV alternator has armature resistance of 0.9 ohm per phase and synchronous reactance of 8 ohm per phase. In each of the following cases the alternator is supplying rated full load current at rated terminal voltage. Calculate emf generated and voltage regulation in each following cases: i) unity P.F. ii) 0.8 P.F. lagging
Given: star, 1500 kVA, 13 kV, , per phase; rated current at rated voltage.
(i) Unity power factor
(ii) 0.8 pf lagging
| Case | E per phase (V) | E line (V) | Regulation |
|---|---|---|---|
| Unity pf | 7584.26 | 13136 | 1.05% |
| 0.8 pf lagging | 7882.95 | 13654 | 5.03% |
Answer: unity pf: E = 7584.3 V/phase, regulation 1.05%; 0.8 lag: E = 7883.0 V/phase, regulation 5.03%.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Emf and regulation of 1500 kVA alternator · Electric Machines II, chapter 1 · asked 2×
- Regulation of delta connected 1600 kVA alternator · Electric Machines II, chapter 1
- Emf, regulation and loading with given load impedance · Electric Machines II, chapter 1
- Synchronous reactance and regulation from test data · Electric Machines II, chapter 1
- Internal emf, no-load emf and regulation · Electric Machines II, chapter 1
- Internal emf and armature reaction reactance · Electric Machines II, chapter 1
- 1600 kVA alternator: emf, regulation, power angle · Electrical Machines, chapter 6
- 1500 kVA alternator: excitation emf, voltage at leading pf · Electrical Machines, chapter 6
- Star alternator supplying delta load (8+j6) · Basic Electrical Engineering, chapter 8
- 5 MVA alternator: regulation and pf for zero regulation · Electrical Machines, chapter 6