Why terminal voltage exceeds emf on capacitive load
Short answer
With a leading pf load, armature reaction is magnetizing, aiding the main flux and raising the air-gap voltage. In phasor form E = V + jI Xs, the IXs drop opposes V, so E can be less than V. Thus terminal voltage exceeds generated EMF, causing voltage rise and negative regulation.
Why the terminal voltage (V) of a synchronous generator is greater than the internal generated emf (E) in case of capacitive load? Explain it with the help of armature reaction and phasor diagram.
For a synchronous generator,
where represents armature reaction and the leakage reactance. With a capacitive (leading pf) load, becomes greater than for two reasons.
1. Armature reaction is magnetising
- With a purely capacitive load, the armature current leads the emf by 90°. The current in a conductor is maximum before the pole axis reaches it, so the armature mmf acts along the field axis and aids the main flux.
- The resultant air-gap flux increases, so the voltage actually generated in the air gap rises.
- For a practical leading pf (e.g. 0.8 lead), one component of armature mmf is magnetising and the other cross-magnetising; the net effect still raises the voltage.
2. Reactance drop opposes the terminal voltage (phasor view)
The drop is perpendicular to . When leads , has a component pointing against , so the vector sum can be shorter than :
I E
\ /'.
\ / '. j I Xs
\/ '.
O----------+ V
I R (small, along I)
From the components (taking current as reference):
Because the reactive term is (minus sign for leading pf), can be less than , i.e. .
Result
- Terminal voltage rises as the capacitive load increases; the external characteristic rises.
- Voltage regulation is negative.
- A smaller field current is needed to keep rated voltage. Example: an alternator feeding a long unloaded cable or a capacitor bank (Ferranti-like rise).
| Load | Armature reaction | vs | Regulation |
|---|---|---|---|
| Lagging | Demagnetising | Positive, large | |
| Unity | Cross-magnetising | slightly | Small positive |
| Leading | Magnetising | (possible) | Negative |
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Load characteristics and capacitive load voltage rise · Electric Machines II, chapter 1 · asked 3×
- Terminal voltage above emf and armature reaction · Electric Machines II, chapter 1
- When terminal voltage is less or more than emf · Electric Machines II, chapter 1
- Internal emf and armature reaction reactance · Electric Machines II, chapter 1
- Armature reaction at different load power factors · Electric Machines II, chapter 1 · asked 7×
- Salient pole generator phasor diagram in per unit · Electric Machines II, chapter 1
- Internal emf, no-load emf and regulation · Electric Machines II, chapter 1
- Synchronous generator load characteristics, capacitive load · Electrical Machines, chapter 6
- Armature reaction in synchronous generator · Electrical Machines, chapter 6
- Armature reaction in synchronous generator · Electrical Machine, chapter 6 · asked 2×
- Synchronous generator working; armature reaction · Electrical Machines, chapter 6