- 2078 Bhadra · 10 marks
Intermittent vs continuous flushing basin
Short answer
Intermittent: area 300 m², total width 6.25 m, length 48 m, two chambers of 3.5 m x 48 m. Continuous with 15% flushing flow: area 345 m², total width 7.19 m, same length 48 m, two chambers of 3.6 m x 48 m; continuous flushing avoids storage and interruption but wastes 0.75 m³/s.
Design a settling basin (i) with intermittent flushing (ii) continuous flushing for a hydroelectric plant by using the simple settling theory. The design discharge of the plant is 5 m³/s and depth of the basin is 3.20 m. Take w = 2.5 cm/s and λ = 1.5. Compare and justify the result. Assume 15% flushing discharge and efficiency = 90%.
Given: m³/s, depth m, m/s, (this coefficient gives the required trap efficiency of about 90% with turbulence), flushing discharge 15% in the continuous case. Assume a horizontal velocity of m/s (within 0.2-0.4 m/s). Simple settling theory: .
(i) Intermittent flushing ( m³/s)
Provide two chambers of 3.5 m x 48 m so that one works while the other is being flushed. Sediment storage is also added (about 1 m) because the sediment stays in the basin between flushes.
(ii) Continuous flushing ( m³/s)
Two chambers of 3.6 m x 48 m. The settled sediment drops continuously into a hopper and is removed by the flushing water of 0.75 m³/s.
Comparison and justification
| Item | Intermittent | Continuous |
|---|---|---|
| Design flow | 5.00 m³/s | 5.75 m³/s |
| Surface area | 300 m² | 345 m² |
| Width (total) | 6.25 m | 7.19 m |
| Length | 48.0 m | 48.0 m |
| Sediment storage | needed (1 m) | not needed |
| Water loss | none during working | 15% of flow |
| Operation | basin must be taken out and flushed | uninterrupted |
The length is the same () while the continuous basin is 15% wider because it carries 15% more water. The continuous basin needs no storage volume, no gate operation and no interruption, but it consumes 0.75 m³/s water all the time; the intermittent basin needs no flushing water except when flushing, but it needs two chambers and storage. For a small plant with little spare water, intermittent flushing is justified; for a plant with silt-laden water and automatic operation, continuous flushing is better.
Answer: (i) 2 chambers of about 3.5 m x 48 m; (ii) 2 chambers of about 3.6 m x 48 m, at a depth of 3.2 m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Continuous flushing settling basin, 95% efficiency · Hydropower Engineering, chapter 5
- Settling basin trap efficiency (Camp's diagram) · Hydropower Engineering, chapter 5
- Settling basin with Hazen coefficient and sediment depth · Hydropower Engineering, chapter 5
- Continuous settling basin (10 m³/s) · Hydropower Engineering, chapter 5
- Single chamber settling basin design (15 m³/s) · Hydropower Engineering, chapter 5
- Settling basin 40 m³/s, 0.15 mm · Hydropower Engineering, chapter 5 · asked 4×
- Settling basin design for 0.15 mm particles · Hydro Power, chapter 5
- Simple Rankine plant 2 MPa / 20 kPa: efficiency, power · Fundamental of Thermodynamics & Heat Transfer, chapter 6
- Settling basin design for 0.2 mm particles · Hydro Power, chapter 5
- Settling basin design for 0.25 mm sediment · Hydro Power, chapter 5