Skip to main content

1200 kVA alternator: voltage at leading pf

Short answer

Rated phase voltage 3810.5 V, cur rent 104.97 A. Exc it ation emf per phase from 0.8 lagging case is 4249 V. For 0.8 lead ing with same excitation and cur rent, solving V = E – I Zs yield s terminal voltage 4560 V per phase (7899 V line).

A 1200 kVA, 6600 V, 3-phase star connected stator of a synchronous generator has armature resistance of 0.4 Ω0.4\ \Omega/phase and synchronous reactance of 6 Ω6\ \Omega/phase. The generator delivers full load current at pf of 0.8 lagging at normal rated voltage. Calculate the terminal voltage for the same excitation and load current at 0.8 pf leading.

Given: 1200 kVA, 6600 V (line), star, Ra=0.4 ΩR_a = 0.4\ \Omega, Xs=6 ΩX_s = 6\ \Omega per phase, full-load current, 0.8 pf lagging at rated voltage. Find the terminal voltage for the same excitation and current at 0.8 pf leading.

Rated quantities

Vph=66003=3810.5 V,I=1200×1033×6600=104.97 AV_{ph} = \frac{6600}{\sqrt3} = 3810.5\ \text{V}, \qquad I = \frac{1200\times10^3}{\sqrt3\times6600} = 104.97\ \text{A} Zs=0.4+j6 ΩZ_s = 0.4 + j6\ \Omega

Excitation emf (0.8 lagging)

Taking VphV_{ph} as reference, I⃗=104.97∠−36.87∘\vec I = 104.97\angle -36.87^\circ A:

E⃗=V⃗+I⃗Zs=3810.5+104.97∠−36.87∘(0.4+j6)\vec E = \vec V + \vec I Z_s = 3810.5 + 104.97\angle-36.87^\circ(0.4 + j6) IR=41.99 V,IXs=629.84 VIR = 41.99\ \text{V},\quad IX_s = 629.84\ \text{V} E=(3810.5+41.99×0.8+629.84×0.6)2+(629.84×0.8−41.99×0.6)2E = \sqrt{(3810.5 + 41.99\times0.8 + 629.84\times0.6)^2 + (629.84\times0.8 - 41.99\times0.6)^2} Eph=4249.05 V  (line 7359.6 V)E_{ph} = 4249.05\ \text{V} \;(\text{line } 7359.6\ \text{V})

Terminal voltage at 0.8 leading (same EE and II)

Now I⃗=104.97∠+36.87∘\vec I = 104.97\angle+36.87^\circ A. The drop I⃗Zs\vec I Z_s has magnitude 104.97×6.0133=631.23104.97\times 6.0133 = 631.23 V at an angle 36.87∘+86.19∘=123.06∘36.87^\circ + 86.19^\circ = 123.06^\circ with respect to VV. For the same excitation, ∣V⃗+I⃗Zs∣=E|\vec V + \vec I Z_s| = E, so

V2+2V(631.23)cos⁡123.06∘+631.232=4249.052V^2 + 2V(631.23)\cos 123.06^\circ + 631.23^2 = 4249.05^2 V2−688.62 V−17.656×106=0V^2 - 688.62\,V - 17.656\times10^{6} = 0 Vph=688.62+688.622+4×17.656×1062=4560.3 VV_{ph} = \frac{688.62 + \sqrt{688.62^2 + 4\times17.656\times10^{6}}}{2} = 4560.3\ \text{V} VL=3×4560.3=7898.7 VV_L = \sqrt3\times 4560.3 = 7898.7\ \text{V}

Answer: terminal voltage at 0.8 leading ≈7899\approx 7899 V (line), i.e. 4560 V per phase, higher than rated because of the leading current (Ferranti-type effect; armature reaction aids the field).

✓ Answer checked by Claude Opus 5.5 (high effort)

All Electrical Machines chapter 6 questions →